ATEX certified D1P 130/145/193/260
Introduction
6 |
©
Danfoss | August 2021

Production place and date of pump

The production location and date of the pump is shown at the first 5 digits of the serial no.
Example: Serial No: N191230941
Five first digits are N1912
N
is the manufacturing location (N=Neumünster)
19
is the year (It stands for the last digit in the possible decade).
12
is the week
The last five digits are a consecutive number.
The ATEX certification of the units are done under the scope of:
"Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the
harmonization of the laws of the Member States relating to equipment and protective systems intended for
use in potentially explosive atmospheres."
With following parameters:
Equipment group: II
Zone: 2 (gas)
Equipment Category: 3G
Temperature class: T5...T3
Explosion protection group: II A
The Conformity Assessment Procedure has to be executed according to Directive 2014/34/EU, annex VIII,
Modul A: Internal Production Control (see article 13, section 1 (c)).
The EU declaration of conformity has to be prepared and issued with regard to annex X of /1/. The
"Essential Health and Safety Requirements" defined by /1/, annex II, have to be considered.

Example ATEX label - D1P

Examples of ATEX pump labels – Pump produced in People's republic of China
1. Manufacturer
2. Location of production
3. ATEX code
4. Material number
5. Model code, including unit and displacement
6. Production code
BC376161003883en-000101