Danfoss PAH 50 Servis Kılavuzu - Sayfa 7
Su Pompası Danfoss PAH 50 için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Danfoss PAH 50 16 sayfaları. Pah series tap water pump disassembling and assembling
Ayrıca Danfoss PAH 50 için: Talimatlar Kılavuzu (13 sayfalar), Talimatlar Kılavuzu (12 sayfalar)
Service guide | Disassembling and assembling PAH 50-100
2.
Inspection
2.1. Port plate and thrust plate
1. Neither port plate nor thrust plate must
show any sign of wear.
3. Check that both O-rings and back-up rings
are not broken and do not show severe
wear.
2.2. Pistons
1. The play in the ball and socket joint must
not exceed 0.1 mm.
2. The thickness of the piston shoes must be
at least 4.3 mm.
180R9098 | 521B1072 | DKCFN.PI.011.NC5.02 | 06.2017
2. Hold a ruler against the surface of the
plates and check the tightness against a
light source.
3. Hold a ruler against the surfaces of the
piston shoes to check that the surfaces
are even and smooth and without any
scratches.
4. It is acceptable that the (black) treated
surfaces of the pistons are partly worn.
7