Danfoss PAHT 256-308 Talimatlar - Sayfa 15
Su Pompası Danfoss PAHT 256-308 için çevrimiçi göz atın veya pdf Talimatlar indirin. Danfoss PAHT 256-308 20 sayfaları. Paht and paht g 256-308 disassembling and assembling
Instruction
Disassembling and assembling PAHT and PAHT G 256-308
6.2. Assembling
1. Carefully push the retainer ring in place.
3. Remove the stop for retainer ball.
5. Tilt the flange and replace the flange
O-ring.
180R9268 / 521B1236 / DKCFN.PI.011.B3.02 / 01.2015
2. Insert the pistons randomly.
4. Place the retainer ring in an odd angle
corresponding to the orientation of the
swash plate.
6. Turn the flange and gently push it into the
housing.
15