Process and PCD data
The process data is spilt up in two parts, a fixed 2
words data part for controlling the VLT frequency
converter and a flexible part, called PCD, that
can consist of 7 words.
Fixed
Fixed
Fixed
User definable
User definable
User definable
Fixed
Fixed
User definable
User definable
MRV PCD1 PCD2
CTW
PCD3
Fixed
Fixed
Fixed
Fixed
Fixed
User definable
User definable
User definable
User definable
User definable
MAV PCD1 PCD2
STW
PCD3
For controlling the VLT 5000 you can select
between the FC profile or Drivecom profile (VLT
parameter 512).
Please have a look at the Interbus operating
instructions for further description of each profile.
PCD data is very useful if you need a constant
update of process parametersvariables, for
example motor current or torque.
Programming example
The following example will show how to set up
process and PCD data.
The chosen profile is Drivecom profile and as PCD
data we will readout parameter 520 Motor current
and 518 Motor frequency. We will also write to
parameter 207 Ramp up time 1 as PCD data.
The data for the VLT frequency converter in our PLC
program starts at address 20. So we have to map
address 20 to the Interbus card in the VLT
frequency converter. This is done with the CMD
tool.
PLC
QW 20
CTW
FC profile
QW 22
MRV
0-100%
QW 24
PCD1
Par. 207
IW 20
STW
FC profile
IW 22
MAV
0-100%
IW 24
PCD1
Par. 520
IW 26
PCD2
Par. 518
First we have to setup the VLT frequency converter
to run with two PCD's. This is done in the
respective parameter 807 PCD size select and
parameter 915/916 PCD config. write/read.
6
PCD4
PCD5 PCD6
PCD7
PCD4
PCD5 PCD6
PCD7
Interbus
CTW
MRV
PCD1
STW
MAV
PCD1
PCD2
®
VLT
5000 and Interbus CMD
PCD 1 has to be set to read the motor current via
parameter 520. This is done by setting sub index 1
in parameter 916 PCD configuration read to 520.
PCD 2 has to be set to read parameter 518 Motor
frequency. Set sub index 2 to 518.
FREQUENCY
0.0 Hz
916 PCD CONFIG. READ
[1]
520
FREQUENCY
0.0 Hz
916 PCD CONFIG. READ
[2]
518
PCD 1 has to be set to write the ramp up time 1 via
parameter 207. This is done by setting sub index 1
in parameter 915 PCD Configuration write to 207.
FREQUENCY
0.0 Hz
915 PCD CONFIG. WRITE
[1]
207
In parameter 807 PCD size select you have to
assign the number of PCD's which the VLT
frequency converter is using.
Choose 2 WORDS [2] and power down the VLT
frequency converter. At next power up the PCD's
will be active.
FREQUENCY
0.0 Hz
807 PCD SIZE SELECT
2 WORDS