Danfoss VLT 6000 series Talimatlar Kılavuzu - Sayfa 5
Medya Dönüştürücü Danfoss VLT 6000 series için çevrimiçi göz atın veya pdf Talimatlar Kılavuzu indirin. Danfoss VLT 6000 series 16 sayfaları.
The top duct work cover is composed of the
following pieces as shown in Photo 8. From
left to right:
•
top duct closing plate
•
drive bracket
•
duct
•
vented top cover
Temporarily install the top duct section as
shown in Photo 10. Use the top duct cover
piece to mark the enclosure top for the open-
ing. Alternately, Drawing 175R5639 can be
used to mark the enclosure for cut-out loca-
tion.
Photo 9. The top duct work partially assem-
bled with bottom flange
Cut the enclosure top. Do not apply gas-
ket to enclosure top (the gasket is part of
the duct work).
Instruction No: 175R5640 V3
Photo 8. Top duct assembly
Photo 10. Top duct work and enclosure
top installed
Photo 11. Enclosure top with cutout
Aug 13, 2008
Page 5