E.
Evenly tighten the three mounting bolts t o secure the
air conditioner to the roof. The mounting bolts should
be tightened t o a torque of 40 to 50 in. Ibs. t o insure
adequate air conditioner t o roof seal.
CAUTION:
DO NOT overtighten the mounting bolts as
this may damage the air conditioner base.
CONNECTION OF POWER SUPPLY TO
AIR CONDITIONER (Refer to FIG. 5)
CAUTION:
Be surepowersupply is OFF before connecting
power suppl y leads t o the air conditioner.
A.
Route the power supply line, previously installed to the
14"
x
14"
opening, into the junction box on the ceiling
template.
B.
Connect power supply line to air conditionerleads with
three appropriate sized twist type wire connectors. Con-
nect white to white, black to black and green to green
or bare copper wire.
C.
Using electricians tape, tape twist connectors firmly to
wires.
D.
Tighten the strain relief onto the powersupply line, t o
hold it firmly in place.
E.
Carefully push excess wire back into junction box and
install cover onto box with screw provided. (The one
blunt point saew in the mounting hardware).
F.
Plug the electrical conduit hanging from the bottom of
the air conditioner into the mating connector on the
junction box located on the ceiling template. (NOTE:
Conduit has a 1.5 inch minimum bending radius).
NOTE: If optional heater is part of this installation, follow the
instructions provided with the dectric heater kit.
AI R BOX INSTALLATION
(Refer to FIG. 4)
A.
Remove the two return air grilk and filters which are
shipped loose in the air box.
B.
Slide the front end of the air box over the shafts of the
thermostat and selector switch.
C.
Install the four screws through legs in air box into the
prepunched holes in the ceiling template.
NOTE:
There are four optional mounting hdes for which no
screws are provided.
D.
Install the return air grills and filters by simply pushing
them into place.
E.
Install the two knobs provided on the ends of the t h e m e
stat and selector switch shafts.
F.
The power supply to the air conditioner may now be
tumed ON.
G .
Your air conditioner is now installed and ready for
operation. Please read the following instructions before
attemotina to run unit.
x
OPERATING INSTRUCTIONS
(Refer to FIG. 6)
A.
Controk
1.
Thermostat (Dial on right side when facing air box)
has a temperature range of
650F in COOL posi-
tion t o 90°F in WARM position.The thermostat
controls the unit wmpressor ON and OFF cycle in
the cooling mode and the electric heater ON and
OFF cycle in the heating mode.
2
Selector Switch (Dial on left side when facing air
box) controls the unit fan speeds, heating mode,
cooling mode and fan mode of operation.
B.
Cooling Operation
1.
Set the thermostat to the position which will
give your &sired comfort level.
2
The selector switch is t o be set as follows:
a.
HIGH COOL:
Selected when maximum
cooling and &humidifying
is required.
b.
MED COOL: Selected when medium woling
is required.
c
LOW COOL: Selected when minimum cool-
ing is required.
Normally this position is
s d d e d for night time operation.
The air conditioner wmpressor will come on and
off
as
cooling is required to maintain your desired
temperature level as set at the thermostat.
NOTE:
The
air conditioner blower runs continuously
t o circulate the air and maintain an even temperature
in the RV. lt does not come on and off with the com-
pressor.
C.
Fan Operation
When you wish to circulate the air inside your RV,
without heating or cooling, select one of the three fan
speeds (HIGH FAN, MED FAN or LOW FAN). The
fan will run continuously and circulate the air in the
RV.
D.
Heating Operation:
(Wnh Optional Electric Heater
Installed).
NOTE: This electric heater will not replace a furnace
for heating your RV in cold weather. It is intended to
remove the chill from the air on cool days or mornings
only.
1.
Set the thermostat to position which will give your
desired comfort level.
2
The selector switch can be set in any of the three
heating positions, but normally it will be placed in
the LOW HEAT position for best results.
The electric heater will turn on and off as heating is
required to maintain your desired temperature level
as
set at thermostat.
NOTE: The air conditioner fan runs continuously to
circulate the air in the RV. lt does not come on and
off with the heater.
E.
Operation of air conditioner WITHOUT Optional Electric
Heater installed.
When the optional electric heater is not installed in the
air conditioner and the sdector switch is in one of the
heating positions (HIGH HEAT, MED HEAT or LOW
HEAT) the air conditioner works as if it were in Fan
Operation. No damage will be caused to the air condi-
tioner when these positions are used.