Duomo KS23 Trio Labstart Manuel - Sayfa 2

Dokunmatik panel Duomo KS23 Trio Labstart için çevrimiçi göz atın veya pdf Manuel indirin. Duomo KS23 Trio Labstart 4 sayfaları. For g621

Duomo KS23 Trio Labstart Manuel
Operation
1. Connect the Trio Labstart to a power supply. A self-
test procedure will run. If a failure is detected the green
POWER light will blink and local buzzer will sound (1,5
Hz).
2. Enter numeric password (1 to 8 characters in length).
At each press the active key will turn to red and a short
tone will confirm the operation. Push the
the code and run the proving test.
(NOTE: In case of incorrect password the buzzer will
make a single long tone (1,5 sec). If the password
matches the buzzer will make 3 short tones.
Press the
at anytime to halt the operation).
3. During the proving stage, the GAS light will flash until
the gas test is completed.
4. A failure on gas will enter an alarm condition, the light
will blink and an audible alarm will sound. The gas valve
will be turned off and the system will require a manual
reset once the problem has been resolved.
5. At any time it is possible to close the GAS Valve and
reach a standby condition by pressing the STOP button.
Password Setup*
To enter password configuration mode, press and hold
keys 1, 6 and 7 together for 5 seconds until the numeric
keyboard backlight turns to red.
2. Enter the numeric password you want to use (1 to 8
characters in length). At each press the active key will
Keypad & Internals
1
4
Enter key
7
Power on
POWER
Air light
Keypad (Fig. 1)
w: www.duomo.co.uk
-
to confirm
2
3
5
6
Abort key
8
9
0
Gas light
WATER
GAS
Stop button
STOP
-
turn off momentarily. Press the
3. Press the CANCEL key to exit configuration mode at
any time, leaving the password unchanged.
*
Default code is 1, 2, 3, 4.
Service Isolation
To enter service isolation mode while in a run status,
press the
the POWER, WATER and GAS lights will flash. Pressing 1,
2 or 3 will turn each of these services on and off. If a
service is off, its light will go out.To finish, press the
Warranties
Duomo UK Ltd guarantees for two years from the date
of manufacture of its product to replace any product or
part thereof which is found to be defective from
manufacture or material failure. Duomo UK Ltd makes
no warranty of merchantability or any other warranty
express or implied. In no event shall Duomo UK Ltd be
liable for consequential or special damages of any
nature which may arise from incorrect application and
installation of this product.
When Duomo UK Ltd products are combined with
equipment manufactured by others and/or integrated
into systems designed or manufactured by others, the
Duomo UK Ltd warranty pertains only to Duomo UK Ltd
products and not to any other equipment or to the
combined system or its overall performance.
Fuse (3A)
t: 01905 797989
-
f: 01905 774296
to confirm the code.
. Buttons 1, 2 and 3 will then turn red and
E E Ph N GND 1 2 3 4 5 6
7 8 9 10 11 12 13 14 15 16 17 18
|
© Duomo (UK) Ltd. 2007
.
Input
terminal
Output
terminal