1.4 Assembly advice

Control units
The reverse side of the control unit has recesses that are used to lock the fastening rail which is fixed to the wall or
the aquarium cabinet with the screw set . The cable to the control unit has a USB connector so that holes of control
unit dimensions do not need to be sawn out of the terrarium cabinet . The USB connector is not designed for a compu-
ter connection . The control unit has a 2 metre cable which permits installation outside the aquarium cabinet as well
as an unobstructed view of all values and status modes .
Connection strips
The connection strip should be screwed to the back or side panel inside the aquarium cabinet to ensure that there is
no contact with the unit in the event of water leakage .
pH-Eletrode
The Dupla pH-Control Pro system is equipped with a BNC connector for pH electrodes .

2. Description of the basic functions

2.1 Function monitoring of external devices

The housing is fitted with LEDs . In operating mode this indicates the active control of the external device .

2.2 Safety shutdown during programming

When entering into the programming mode, both slots are deactivated for safety reasons .

2.3 Safeguard function

To protect electronic components, a delay of 60 seconds is set between 2 switching states before the respective slot
becomes active again .

2.4 Interval reset

Irrespective of the time of day, all programmed intervals start when the device is switched on or the menu is quit .

2.5 Return function

The Dupla pH-Control Pro automatically returns to the operating mode when no button has been pressed for a period
of 90 seconds while in the programming mode .

2.6 Memory function

To safeguard against loss of data in the event of a power failure, the Dupla pH-Control Pro stores all set values . The
unit will continue to calculate the time for up to five hours after such an event, so the clock does not need to be reset
after brief power failures .

2.7 Malfunction displaying

In the event of a pH-Electrode defect
will be displayed . A programming error in the timer programming for slot
2 is indicated by E05 .