AudioControl M4800 Kullanıcı Kılavuzu - Sayfa 5
Amplifikatör AudioControl M4800 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. AudioControl M4800 10 sayfaları. Crestron driver
Module Definitions
AudioControl_{Model} _Comms_VX_XX.umc
The central module handling all communications between Crestron and the amplifier. This
module will require a "TCP/IP Client" device to be configured in the SIMPL Windows
program, with the IP address of the amplifier defined, and the port defined as "23".
Signal Name
CommsConnected
CommsRx
ZoneCommsTx
GroupCommsTx
SetZone[x]_ToGroup1
SetZone[x]_ToGroup2
SetZone[x]_ToGroup3
SetZone[x]_ToGroup4
Poll Interval
CommsConnected
CommsTx
Zone1CommsTx
Zone10CommsTx
Group1CommsTx
Group 10CommsTx
Zone[x]_ToGroup1
Zone[x]_ToGroup2
Zone[x]_ToGroup3
Zone[x]_ToGroup4
*AudioControl supports 4 groups; these groups can contain any number of zones. A zone
can only be associated to one group at any one time. If you set the zone to a group when
the zone is already associated to another group, then the zone will be removed from its
current group and added to the new group.
SetZone[x]_ToGroup[x]
Type
Description
Input
Signal FROM TCP/IP Client 'Connect-F'.
Signal FROM TCP/IP Client 'RX$'.
Signal FROM Zone modules
Signal FROM Group modules
Adding and removing a zone to a group*
Time interval between polling attempts. Polling
will keep the module feedback in sync with the
amplifier when changes are made to the device
PARAMETER
locally. (The default is 30 seconds. If 0 seconds is
set, polling is disabled).
OUTPUT
Signal TO TCP/IP Client 'Connect'.
OUTPUT
Signal TO TCP/IP Client 'TX$'.
Signal
AudioControl_ZoneAnalogue.umc modules.
1 to 8
–
OUTPUT
Signal
AudioControl_ZoneDigital.umc modules.
9 and 10
–
Signal TO one or more AudioControl_Group.umc
OUTPUT
modules.
Feedback indicating which zones are in Gwhich
groups.
OUTPUT
works like a toggle button – pulse it to add the zone to the group.
Audio Control M6400 / M4800 / D4600
Crestron Driver User Guide
TO
one
TO
one
or
more
or
more
4