Application Note
Modulation Fidelity
•
Symbol Deviation
•
Bit Error Rate Calculation
•
Radio Setup
Connect radio's Programming cable to USB on PC
•
Setup Tuner Software
•
Open APX Tuner software on PC
o
"Read Device" > wait... > Record radio serial number
o
"Performance Testing" > "Transmitter Test Pattern"
o
"Test Pattern Type" > "Phase 2 Digital – 1031 Hz Test Pattern"
o
"TX Power" > "Low"
o
Record displayed Test Frequency
o
R8000 Setup
Connect Radio RF antenna connector to R8000 RF In/Out port
•
Return Analyzer to factory default settings
•
"Test"
o
"Presets"
o
"Load Factory Configuration"
o
Set Test Mode to P25 Phase 2
•
"Test" (if presets are shown, press ESC)
o
"Test Mode" > "More (1 of 2)" > "P25 II"
o
"ESC" to main screen
o
Configure Display to Eye Diagram
•
"Display Zone" or "4" shortcut key
o
"Select Display" > "Eye Diagram" on horizontal soft key
o
"ESC"
o
METER Zone or "7" shortcut key
o
Select Meter" > "Constellation
o
"ESC"
o
Configure Modulation Type and Test Pattern
•
"P25 II" Zone or "2" shortcut key
o
"Modulation Type"
o
If testing portable/mobile: "H-CPM"; if testing base station: "H-DQPSK"
o
"Test Pattern" > "1031 Hz Tone"
o
Configure R8000 monitor frequency
•
"RF zone" or "1" shortcut key
o
"Monitor Frequency" > Enter Tuner test frequency > "Enter"
o
Begin Test
Verify RF cable present from Radio to R8000
•
In Tuner, select "PTT Toggle" to key the radio
•
If R8000 and Radio configured properly, Eye Diagram and Constellation Meter will update.
•
In "P25 II" Zone, record readings:
•
"Mod Fidelity" (standard limit < 5%)
o
"Symbol Deviation" (standard limits 2995 Hz to 3310 Hz)
o
Perform Bit Error Rate (BER) test
•
"P25 II" zone
o
"BER Test" > "Start"
o
Record BER (standard limit < 0.01%)
o
"BER Test" > "Stop"
o
Testing Motorola P25 Phase 2 Radios Using the Freedom Communications System Analyzers
3