7. Remove DCR programming
1. Log into the Configuration Manager of the Commander/RubyCi.
2. Navigate to Forecourt > Fuel > Fuel Config – Pending > Fueling Positions.
See figure 5 on page 15.
Uncheck 'DCR In Dispenser' for each upgraded fueling position and SAVE.
3. Navigate to Tools > Managed Modules > Current Configurations > Host Names -
sitecontroller > Select Module - DCR Driver > DCR Positions – Advanced Settings.
See figure 6 on page 15.
Remove the channel programming for each upgraded DCR Position and SAVE.
4. Initialize Fuel and DCR's.
The Easy Pump should now be operational at each upgraded fueling point.
Once all fueling points have been upgraded to
The Easy Pump, remove the DCR
5. Navigate to Tools > Managed Modules > Current Configurations > Host Names –
sitecontroller > Select Module – DCR Driver > DCR Channel 01 – Advanced
Settings. See figure 7 on page 15.
6. Initialize Fuel and DCR's, including Drivers.
Freedom Easy Pump: Mako
Remove DCR Family type
Remove Port Name
Uncheck Enable and SAVE
driver.