3Ware RAID Controllers Ürün Kılavuzu - Sayfa 8
Ağ Kartı 3Ware RAID Controllers için çevrimiçi göz atın veya pdf Ürün Kılavuzu indirin. 3Ware RAID Controllers 11 sayfaları. Hardware raid controllers
battery backup Units
bbU-MoDUle-03
bbU Availability features
•
Maximum reliability with cached write data protection
•
Missing Array Detection
•
Write Journaling
•
Dynamic Sector Repair
•
Drive Power-On Reset Detection
•
Extensive Drive Timeout Recovery
•
Out of Band Signaling Retry
•
Up to 72 hours of data protection in the event of
power failure
battery Mounting option
•
Battery attaches directly to the BBU Control Module
•
The BBU Control module mounts directly to the
RAID controller
Compatible RAID Controllers
•
3ware 9650SE
•
3ware 9550SXU
3ware RAID Controller
features and benefits
StorSwitch
™
Non-blocking switch fabric architecture
StorSave
Powerful reliability enhancements
StreamFusion
Intelligent cache algorithm
Multi-lane
™
Award-winning connector system
RAID 6
(On select 3ware 9690SA and 9650SE
controllers)
Advanced Content Streaming
(9690SA and 9650SE Controllers)
Hybrid Initialization
(9690SA and 9650SE Controllers)
Accelerated RAID Recovery
(9690SA and 9650SE Controllers)
bbU-MoDUle-04
bbU Availability features
•
Includes all BBU-MODULE-03 features
+ Remote battery mounting capability for design flexibility
battery Mounting options
•
Battery can attach to a BBU daughter card in various positions
•
Battery can attach remotely to chassis wall, both internally and externally
•
Remote mounting kit without battery available separately
Compatible
RAID Controllers
•
3ware 9690SA
•
3ware 9650SE
•
3ware 9550SXU
2
2
1
2
1
2
Battery placement options
Maximizes controller throughput by allowing concurrent communications with all attached
SATA drives through a pool of 32 direct memory access (DMA) channels.
Achieves unmatched data protection while maximizing performance in critical RAID modes
when data availability, accessibility, and data protection are most needed.
Maximizes application performance under heavy loads by dynamically allocating controller
cache for maximum bandwidth
Dramatically increases subsystem reliability by radically reducing cable count and improves airflow
Two sets of parity are simultaneously calculated, written, and rotated across all the drives.
This allows the array to survive up to two drive failures without losing data, for significantly
improved fault tolerance.
Aggressively Caches write and read data and improves write and read content streaming.
Provides intelligent caching algorithms to improve application performance in real world cases.
Faster foreground initialization for RAID 5 and RAID 6 arrays with 16 or more drives.
Fastest background initialization for newly created arrays.
Faster rebuild completion. Shorter verify/initialization.
3
3
2
2
3
3
2
2
3
1
1
2
2
3
3
1
1
1
1
1
3
2
3
2
3
2
2
3
3
1
2
3
1
1
2
3
3
3
Performance
Data Protection
Performance
Reliability & Convenience
Data Protection
Application Performance
Array Availability
and Performance
Data Accessibility
and Availability
8