Daniela DAN55UCB Kullanıcı Kılavuzu - Sayfa 8
Havalandırma Davlumbazı Daniela DAN55UCB için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Daniela DAN55UCB 17 sayfaları. Ducted under cupboard
RECIRCULATING & DUCTING VERSION INSTALLATION:
INSTALLATION OF ELECTRICAL
•
The electrical wiring must be done by a qualified technician in accordance with all
Use an outlet exhaust duct with: Minimum indispensable length; Minimum possible blends
applicable codes and standards.
( maximum angle of bend 90°C); Certified material ( according to local, building and fire
•
Turn o electrical power at the service entrance before wiring.
regulations); and as smooth as possible inside. It is also avliavle to avoid any drastic changes
•
If the supply cord is damaged, it must be replaced by the manufacturer or a Daniela
in duct cross- section ( recommended diameter: 150mm).
Appliances Pty Ltd service agent, to avoid a hazard.
•
Do not use the plug and an extension cord other than the ones initially supplied
For Recirculation version, please consider some outlets for clean air returns into the room.
with the hood.
INSTALLATION
•
Before beginning installation, to better handle the hood, we advise removing the
aluminium filter.
•
Before fixing, the outlet exhaust duct for air evacuation to the outside must be installed.
FITTING UNDER WALL UNIT
NOTE: The distance between the hob and the lower part of the hood must be at least 650mm
1. Before fixing the hood to the unit, cut the hole in order to fit the range hood under the cabinet.
for an electric hob and 750mm for a gas hob.
Please check the size below..
FITTING UNDER WALL UNIT
1.
Before fixing the hood to the wall unit, drill a hole of 130mm diameter in the wall unit.
2.
In any case, check the position of the power outlet and consider where the power cable
will run, since the hole might have to be made in the wall unit to accommodate it.
3.
Drill 4 holes into the wall unit, respecting the distance indicated. Push the hood up against
the wall unit and insert the 4 screws operating from inside the wall unit.
4.
Make the electrical connection.
2. Drill 4*O5 mounting holes in the top of the cabinet and drill O 160mm air outlet hole..
PAGE 8
D A N I E L A
P
I
02 9604 1226
E
A P P L I A N C E S
INSTALLATION & USE
I
150mm
W
|
danielaappliances.com.au
PA G E 7
D A N I E L A
A P P L I A N C E S