Abus AZSG10005 Kurulum Talimatları ve Kullanım Kılavuzu - Sayfa 14
Güvenlik Sistemi Abus AZSG10005 için çevrimiçi göz atın veya pdf Kurulum Talimatları ve Kullanım Kılavuzu indirin. Abus AZSG10005 19 sayfaları. Wired outdoor siren
Step 5: Connecting the cable
Strip the cable to sufficient length and remove insulation from the individual wires in order to
connect these.
Remove the cover over the screw terminal on the inner housing by pressing together the
lateral terminals upwards and lifting up the cover.
Then connect the individual wires to the respective screw terminal and feed the wires
individually outwards through the openings provided in the inner housing.
See the label on the cover of the inner housing for how to assign the terminal connectors.
Every connector is marked on the sticker.
Description of the terminals:
STB
Signal from the alarm panel to activate the flashing light
TRIG
Signal from the alarm panel to activate the siren
- HOLD OFF
Permanent 0 V fitting from the alarm panel
+ HOLD OFF
Permanent 12 V fitting from the alarm panel
RTN
Tamper notification to the alarm panel
FAULT
Closed circuit, which opens in the case of fault (both fault terminals)
FAULT
Closed circuit, which opens in the case of fault (both fault terminals)
TEST
+ve signal from the alarm panel to activate routine self tests
Step 5: Connecting the battery
Connect the plug of the already inserted battery (No 3 Fig. 2) to the battery holder (No 5 Fig.
2).
Step 6: Closing the sounder
Ensure that the inner housing is sitting firmly in the catch in the middle of the housing.
Close the inner housing with the terminal cover (No 7 Fig. 2).
Snap shut the sounder lid and screw this in tightly with the cover fixing screw.
Finally, affix the screw cover over the cover fixing screw.
Installation
14