Dankoff Solar Water Feature Kurulum ve Servis Kılavuzu - Sayfa 16
Su Pompası Dankoff Solar Water Feature için çevrimiçi göz atın veya pdf Kurulum ve Servis Kılavuzu indirin. Dankoff Solar Water Feature 18 sayfaları. Solution kit
16
8. MAINTENANCE
Shaft Seals - Seals may last for a few years, but if the water contains abrasive silt, the seals will wear faster. Seals
will be quickly ruined if the pump runs dry. You can purchase spare seals from your Dankoff Solar dealer and MUST
be installed correctly. The smooth white ceramic face must face outward, away from the motor. The part with the
spring presses over the shaft. The all-black end must contact the white ceramic face. The metal and rubber end
faces away from the motor.
Seal and Gasket Kits
If last digit of the pump model number is 1, 2, 3, or 4 — order Dankoff Solar item #37690
If last digit of the pump model number is 5 or 6 — order Dankoff Solar item #37691
Seal and Gasket Kits for High Temperature pumps
If last digit of the pump model number is 1, 2, 3, or 4 — order Dankoff Solar item #37695
If last digit of the pump model number is 5 or 6 — order Dankoff Solar item #37696
The seal is an industry-standard pump seal for 5/8" shaft. In case of emergency, you may be able to obtain one
from a local pump supplier or electrical repair shop. If the paper pump gasket is damaged, a new one can be cut
from thick paper. Manila file folders works fine.
Before pressing the seal parts into place, use your finger to wipe a small amount of oil or grease onto the cast iron,
rubber and shaft surfaces. This will make installation and service much easier. DO NOT get any lubricant onto the
mating white and black faces of the seal. Always replace BOTH parts of the seal (the black part and the black &
white part)
Pump Head – The pump head is maintenance-free. Do not remove its front plate or otherwise tamper with it. The
pump head is not user repairable. It is easy to dissemble, but difficult to reassemble without special tools.
Motor Brushes – Motor Brushes: Typical brush life peak hours = working voltage X 800 / 3rd digit of model
number. EXAMPLE: PV-Direct curve #60 is Model 7526 working at 30V. Typical brush life = 30 X 800 / 2 = 12,000
peak hours. This represents about 5-8 years of service. Your result may differ. New Brushes measure 1.25 inches
(31 cm) in length. You can measure wear after a period of time, to predict the brush life. Worn brushes will not
effect performance, until they are worn to about 1/2 inch (1 cm.). At that point, to motor will stop as contact is
broken. Replacement brushes may be obtained from your dealer or the factory.
Motor Bearings - Ball bearings in the motor are lubricated for life and do not require maintenance. If water enters
the motor accidently, it will damage the bearings. Replacement bearings can be obtained from your Dankoff Solar
dealer. Purchase two bearings #6203Z.