Conrad-johnson design ET2 Vacuum Kullanıcı El Kitabı - Sayfa 13

Amplifikatör Conrad-johnson design ET2 Vacuum için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Conrad-johnson design ET2 Vacuum 13 sayfaları. Tube preamplifier

Conrad-johnson design ET2 Vacuum Kullanıcı El Kitabı
S
pecifications
Line Stage
Gain: 28 dB
Maximum Output: 5.5 Vrms
Bandpass: 2Hz to more than 100kHz
Hum and Noise: 95 dB below 2.5V output
Distortion at 1.0 V output: less than .1% THD or IMD
Phase: inverts phase of all inputs (including phono) at main out
Ouput Impedance: 200 ohms
Mechanical
Dimensions: 16.125"D x 19"W x 4.625"H
Net Weight: 18.5 lb net
Fuses
The ET2 has two power transformers each of which is protected by
a fuse. These fuses (F1 and F2) are located on the main pc board
near the transformers. There is also an ac mains fuse (F3) located
in the ac mains inlet socket on the back of the unit. A failure of any
of these fuses is a symptom of a more serious problem, and a
competent service technician should be consulted. In no event
should a fuse be replaced with a value or type different than that
originally supplied. Correct fuse values are:
If configured for 100 or 120V:
If configured for 220 or 240V:
F1 3AG type 3/4 amp, slow blow
F2 3AG type 1/2 amp, fast blow
F3
5 x 20mm T800 (800 ma slow blow)
F1
3AG type 1/2 amp, slow blow
F2 3AG type 1/4 amp, fast blow
F3
5 x 20mm T400 (400 ma slow blow)
ET2 Owner's Manual
12