7. Adjustment of Camera:
1

8. Installation of Monitor Unit:

Alterations / Errors Reserved
Cassens & Plath GmbH, Am Lunedeich 131, D-27572 Bremerhaven, Germany, tel +49(0)471 483 999 0, fax +49(0)471 483 999 10
www.cassens-plath.de,
2
208mm
To adjust camera loosen arrest knob (1). Rotate
camera until image is centered. Fix camera in
that position with arrest knob. After that focus
camera by turning the camera lens (2).
Cut out: 190mm x 140mm
Monitor will be snapped in frame.
Plug monitor jack into socket of
junction box 1. For wiring refer to
paragraph 5.
164,5mm