Air circulation system

Illustration
Air circulation sys-
tem
14
This illustrates the air circulation system:
Fig. 3
The air circulation system consists of a direct driven fan  and internal air passages
from the air inlet  to the heated air outlet . The space heater can operate as a totally
external (fresh) air heater or in a recirculation mode utilising most of the air from the
heated space. In recirculation mode it is possible to run with up to 476 m3/h fresh air
by opening the round fresh air intake  on the side of the unit.
Four air duct connections are provided, two on the supply discharge side  and two on
the inlet/return airside .
The connectors are compatible with male spigots/connectors for 225 mm flexible ducts
which are fastened with rubber latches.
No.
Part
Heated air outlet
Direct driven fan
Air inlet
Fresh air intake