The flue must be appropriated to the appliance used.
9.3 Smoke comes out
Check if the primary air register is opened.
Check if the entrance of the chimney presents leaks.
Check if the ash or other residuals have obstructed the draining pipe.
Insufficient draught.
-
Check the draught in the flue.
-
Check the gaskets.
-
9.4 The glass gets dirty in a short time
Damp wood: use dry wood
Wrong fuels (see materials allowed)
Too much fuel in the hearth space
Draught insufficient (see connection to the flue)
Wrong regulation: if the secondary air register is closed, the glass gets dirty in a short time.
9.5 Condensation
During the initial lightings the condensation is normal, because the built-in materials contain dampness.
If the problem goes on, check the wood you use; it must not be damp or badly dried.
The chimney must not have defects and it must not cool down too quickly the draining gas.
Attention: The manufacturer exclusively uses materials which DO NOT represent health hazards.
The manufacturer reserves the right to make modifications to the appearance, to the dimensions or to the
models themselves without previous notice.
10. TECHNICAL DESCRIPTION
10.1 Description
The stove is suitable to heat living spaces or to support an insufficient centralized heating system. As fuel,
it is possible to use wood logs. The stove is made of cast iron and steel plates. The hearth is internally
sheathed with single sheet in cast iron and inside it there is a rotatable and extractable grate. The hearth is
equipped with a panoramic door with glass (resistant up 700 °C). This allows a wonderful view on the
burning flames and maximum heat distribution.
The heating of the environment is achieved:
Through the panoramic glass and the external surfaces of the stove, the heat is radiated into the
environment.
The chimney stove is equipped with registers of primary and secondary air by which the combustion air is
(max.20%
moisture)