Danville Signal Processing DSP-8200d Kullanım Kılavuzu - Sayfa 10
Kayıt Ekipmanları Danville Signal Processing DSP-8200d için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. Danville Signal Processing DSP-8200d 14 sayfaları. Tone suppression & noise reduction system
Control Module Jumper Configuration
A 3-pin header (JH1) configures the relay switch closure. This header is located near the
front panel just behind the BNC connector.
If a system failure occurs, the switch closure is open when the shorting jumper is in
the NC position.
If a system failure occurs, the switch closure is closed when the shorting jumper is in
the NO position.
The factory default position is NC (closed during normal operation and open during
a failure).
Control Module Cables
The Control Module may be connected to a computer using either a RS-232 connec-
tion or a USB connection.
A standard DB9F to DB9M cable with no twists is used for the RS-232 connection.
A standard USB cable with a B connector on the Control Module side is used for a USB
connection. Consult the factory for USB device drivers.
Terminal Configuration
Port Settings should be set as listed:
Bits per second:
Data bits:
Parity:
Stop bits:
Flow control:
38400
8
None
1
None
Page 10