Insert the black plug of the K-type thermocouple to the adaptor "-" socket and the
red plug to the adaptor "+" socket.
•
Carefully touch the end of the thermocouple to the object to be measured.
•
Wait a short while and read the display.
MEASURING CAPACITANCE
•
Connect the black test lead to the "COM" jack and the red to the "mA" jack.
•
Set the function switch to F position (note: the polarity of the red lead is positive).
•
Connect the test leads across the capacitor under measurement and ensure you
observe the polarity of the connection.
•
Note: To avoid damage to the meter, disconnect the circuit power and discharge
all high-voltage capacitors before measuring capacitance. The tested capacitor
should be discharged before the testing procedure. Never apply voltage to the
input, or serious damage may result.
MEASURING FREQUENCY
•
Set the function range switch to the required Hz position.
•
Connect the black test lead to the "COM" jack and the red to the "VΩ" jack (note:
the polarity of the red test lead is positive).
•
Connect the test leads across the load to be measured.
Note: Do not apply more than 250V rms to the input. Indication is possible for a voltage
higher than 100V rms, but may be out of specification.
AUTO POWER OFF
•
If you do not operate the meter for 15 minutes, it will turn off automatically. To
switch it on again push the power button twice.
REPLACING THE BATTERY & FUSE
•
Prior to replacing the battery or fuse, disconnect the test leads and ensure the
power is off.
•
If the low battery symbol appears on the display it indicates that the battery should
be replaced. Remove the screws and open the back case, replace the old battery
with the new battery (9V IEC 6F22, NEDA 1604 or equivalent specification).
•
Snap the battery connector leads to the terminals of a new battery and reinsert the
battery into the case top. Dress the battery leads so that they will not be pinched
between the case bottom and top.
•
The meter is protected by a fuse:
- mA: F0.5A/600V fast, breaking capacity is 10kA, dimensions ɸ5x20mm
- 10A: F10A/600V fast, breaking capacity is 10kA, dimensions ɸ5x20mm
- A (D03143): F2A/600V fast, breaking cacpacity is 10kA, dimensions ɸ5x20mm
•
Replace the case bottom and reinstall the three screws. Never operate the meter
unless the case bottom is fully closed.
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF
ELECTRICAL & ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste Electrical
& Electronic Equipment (WEEE). Any WEEE marked products must not be mixed with
general household waste, but kept separate for the treatment, recovery and recycling
of the materials used. Contact your local authority for details of recycling schemes in
your area.