Powering
The EIDX requires low-voltage DC power via a four-pin removable keyed
connector. Power conductors can be stranded (16–18 AWG) or solid (16–22
AWG). Consult the Specifications section for power requirements. The various
power options are explained below.
NOTE:
This device is intended for use with Class 2 circuits.
DC Powered
The EIDX accepts a voltage of 48 VDC ±10% and draws current commensurate
with power consumption. Power conductors should be sized accordingly. COM
and the equipment chassis are isolated from zero volts. The input connections are
reverse-polarity protected.
Figure 4 — DC Powered
Figure 5 — Redundant DC Powered
Redundant DC Powered
Redundant diode-isolated DC power inputs are provided so the EIDX can operate
despite the loss of primary power. Both sources must provide required power.
LED Indicators
Power — This LED glows green when proper power is applied to the EIDX.
Status — This bicolour LED will be green in an operational state and red in a
fault state. The green LED blinks periodically to indicate the management CPU
is fully operational.
Port — Each port has an associated bicolour LED which glows green when a
valid Ethernet link has been established at 100 Mbps but yellow if the data rate
is 10 Mbps. The LED flashes when data transfer is occurring.
PoE Power — This LED glows green when PoE power is being delivered to a
powered device (PD).
48V — This LED glows green when 48 VDC is present for the PoE ports.
Fault — This LED glows red to indicate an error condition on the PoE ports.