• Touchswitch™ wiring is low voltage DC.
• Use shielded cable and keep separate from high voltage cable.
• Never run Touchswitch™ cables in the same conduit as 3-phase motor cables.
• Track belts and commission plant prior to installing Touchswitches.
• Fabricated brackets must be built rigid enough to take pressure from a misaligned belt.
Install Touchswitches on machinery only after they have been wired to a power source, and can
alarm / shutdown the equipment being monitored.
All wiring must be in accordance with local and national electrical codes and should be undertaken by an
experienced and qualified electrician.
If required by local installation code, use dust/liquid tight flexible metal conduit with approved fittings to
protect the sensor cables. Conduit systems can channel water due to ingress and condensation directly
to sensors and sensor connections which over time will adversely affect the performance of the system.
As such, the installation of low point conduit drains is recommended for all sensors.
Mount a suitable junction box within 3m (9 ft.) of the sensor, and using a suitable conduit to protect the
cables, make the necessary wiring connections inside this junction box. A 3 meter, PVC coated cable
connected to the sensor contains the following 22 AWG wires:
RED -
BLACK -
GREEN -
WHITE -
BLUE -
ORANGE -
WARNING
NOTE
STANDARD WIRING
12-24 VDC
0 VDC
Ground
Solid State Relay Common
Solid State Relay Normally Open (Sensor Output)
Not connected