11-3. Automatic frequency setting
The automatic frequency setting function allows the controller to find the optimum resonance point when the resonance point of the vibrator is unknown.
It is a convenient function.
First, you need to have a vibration sensor, set the proper voltage after connecting the vibrator, and proceed.
If there is no vibration sensor or the output voltage is set too low, the resonance point can not be found.
Turn the selector
Set to frequency automatic setting mode.
The automatic frequency setting is about 6 minutes. If you press the "STOP" button, it will stop.
You can only stop with the STOP button, but not other buttons.
12. Protection and Notification Features
This product is designed to protect the product if an error occurs due to user's carelessness or environmental factors.
The protection function operates and an error code is displayed on the display window.
The following explains the error code and its countermeasures according to the error code.
Error display
EEPROM Write Error
Over Heat Error (Over Heat)
Internal heat sink overheated
Over current error (Over Current)
Capacity over current flow or load side
short
Press the selector button to start.
As the display rotates
Tells you that it is working
`
Above
- Needs repair.
- Turn off the power, remove the cause of overheating,
Wait a certain amount of time and use.'
- Turn off the power and remove the cause of the overcurrent.
Basic display after completion
How to cope