Apollo Spas Triton Kullanıcı El Kitabı - Sayfa 19

Sıcak Küvet Apollo Spas Triton için çevrimiçi göz atın veya pdf Kullanıcı El Kitabı indirin. Apollo Spas Triton 20 sayfaları.

Troubleshooting Spa Problems
1. Nothing functions: The GFCI Breaker has tripped or there is a power failure. Test GFCI
Breaker. Turn breaker back on and see if spa powers up, if not contact your factory authorized dealer.
2. Spa does not heat: Check to see if the heat indicator is on or there are any error messages on the topside
control panel. If the heat indicator is on and no error message appears contact your factory authorized dealer.
3. Poor Jet Pressure: First check to see that the jet(s) are turned on fully. Check your filter to see if it's clogged
or dirty. Next, check to see if the jet(s) are obstructed or if the venturi air dial is turned on. Finally, check to see
if the jet(s) are surging. If so, your pump is cavitating (sucking in air). This usually occurs when the water level
is too low and can be solved by adding water to the spa. Adjust Filter Weir to increase or decrease feed flow. If
the problem still persists, contact your factory authorized dealer.
4. Spa comes on by itself: This function is normal when heating and filtering. No action required.
5. Spa doesn't drain completely: The spa is drained by gravity. It will not always drain fully. It is not necessary
to drain the spa in its entirety except when winterizing the spa. If you wish to remove the last little bit of water,
we recommend you vacuum it out with a wet/dry vacuum.
18