IRIS-4 160
Quick Installation and
Maintenance Guide

8. SPeCIFICatIonS

transmission paths

Ethernet

Standard
UTP 10/100 Base T with auto-negotiation
Connection
RJ45 socket for CAT5 cabling
IP addressing
Dynamic (DHCP) or fixed
Fault detection
Loss of Ethernet synchronisation
Wi-Fi
Standard
IEEE 802 . 1 1 b/g
Connection
2 . 4 GHz b/g/n with internal PCB chip antenna
Fault detection
Loss of association/data
4G/3G/2G
Frequencies
Penta band LTE (4G)
800/900/1800 MHz
2100/2600 MHz
Dual band UMTS (3G)
900/2100 MHz
Dual band GSM (2G)
900/1800 MHz
Connection
SMA socket for antenna
Fault detection
Loss of registration with network
IP
TCP ports (outbound)
53165 (Alarms & Polling), 51292 (Diagnostic & Reflashing),
10001 (Upload/Download)
Alarm transmission
Interface to Monitoring Centre
IRIS Secure Apps or IRIS Management Suite via
EN 50136-2 pass-through mode
Dial capture interface to alarm panel
Two wire interface via terminal block
Note: Cabling must not exceed 3 meters
Serial interface to alarm panel
RS485, TTL, RS232 Note: RS232 cabling must not exceed 3 meters
18
IRIS-4 160
transmission paths
Alarm transmission
PIN Inputs interface to alarm panel
Maximum input voltage range 0V to +24V
Input 'low' (alarm) threshold < 1V
Input 'high' (restore) threshold > 2V
Internal pull-up impedance 10K to 3 . 3 V supply
Alarm protocols
SIA (level 1 to 3) reference SIA DC-03-1990 . 0 1(R2003 . 1 0)
Contact ID reference SIA DC-05-1999 . 0 9
Fast format (Scancom) for dial capture and serial connections
Robofon (Dial capture only)
Telim (Dial capture only)
CESA (Dial capture only)
Tamper detection reporting to
Dial capture interface, lid & back tamper, serial interface, pin inputs
Monitoring Centre
Fault reporting to Monitoring Centre External power supply fail, low battery, transmission interface/path fault
Relay outputs
Maximum operating voltage
24V DC
Maximum current rating
100mA DC
Power supply
Supply voltage
9V to 17V DC
Typical current
83mA @ 12V DC
Maximum current
1A @ 12V DC
Recommended external PSU
Note: For Radio Equipment Directive the power cable needs to be
no longer than 3 meters in length
Power storage
Storage device type
Storage device capacity
Storage device time to recharge to 80% capacity
Storage device – voltage at which fault is reported
Storage device – voltage at which fault is restored
Storage device – over voltage protection triggered
Storage device – deep discharge protection
Environmental
Operating temperature range
-10°C to 55°C
Operating humidity range
95% max ., non-condensing
Weights and Dimensions
Physical dimensions (L x W x D)
11 . 5 cm x 17 . 5 cm x 4 . 5 cm
PCB weight
400 grams
Fully packaged weight
600 grams
IRIS-4 160
IRIS-4 160
Note:
Cabling must not
exceed 3 meters
12V DC 1A 12 Watt
4 x AA NiMH rechargeable batteries
2000mAh
32 hours
4 . 5 V DC
5V DC
6 . 5 V DC
4V DC
19