AddSecure IRIS-4 Hızlı Kurulum ve Bakım Kılavuzu - Sayfa 6
Dokunmatik terminaller AddSecure IRIS-4 için çevrimiçi göz atın veya pdf Hızlı Kurulum ve Bakım Kılavuzu indirin. AddSecure IRIS-4 9 sayfaları.
IRIS-4
2 Series
Quick Installation and
Maintenance Guide
IRIS-4 200 or 240 with 2/3/4g connection:
2/3/4G Network Scan
Select the 'Run Network Scan' . The scan must be
carried out without the SIM card fitted . The dialler
listens for every base station in range, requests oper-
ator name and records the signal strength . This will
take a few minutes to complete .
For a reliable 2/3/4G connection it is recommended
that for the chosen network (SIM card) used there
should be at least two base stations with signal
strength (CSQ ) of 10 or more .
If the signal strength is below or close to minimum
then try to reposition the antenna or IRIS-4 2 Series
dialler in different location or you can use an external
building or high gain antenna (if necessary), and
rerun the network scan to check signal strength .
Once you have the required 2/3/4G signal strength
10
power down the dialler and insert the SIM card into
the SIM card holder, then power the dialler back up .
Go back into the 'Installers Menu' and enter in the
installer code that you had setup beforehand and
then select the Installation Wizard as indicated next .
IRIS-4 220 or 240 without 2/3/4g
or after network scan completed:
Installation Wizard
Select the Installation Wizard and follow the on
screen prompts .
Once Installation Wizard is completed and any
additional panel interface configuration via the
settings menu you will need to check/configure
the panel for the connection method you are using:
6.9. Panel Configuration
Panel configuration for dial capture
If connecting the IRIS-4 2 Series dialler via the dial
capture method which is connecting the Telecoms
module of the panel to the dial port of the IRIS-4
2 Series, the following options will need to be
configured:
Telephone Number = the 12 digit format of the
Monitoring Centre IP address
(e . g . 192 . 1 68 . 0 . 3 4 would become 192168000034) .
Account Number: 4 – 6 digit account number
allocated by the Monitoring Centre .
Note: If the 'Alarm override' mode is selected, the
IRIS-4 2 Series dialler replaces the phone number
and the account number used by the alarm dialler
with the IP address of the monitoring centre and
account number entered during configuration, so
there is no need to change any settings on the
alarm panel.
Alarm panel integration
e.g. Honeywell Galaxy (RS485 connection).
If you have not already made the changes to the rel-
evant configurations in the panel for the integration,
and require further details on these configurations
then please download the full panel installation
manual from http://www . a ddsecure . c om .
6.10. testing
Once all configurations are complete, perform a full
commissioning test with the Monitoring Centre . This
will normally involve testing normal alarm transmis-
sions from the alarm panel over all communication
paths to the Monitoring Centre . Verifying acknowl-
edgement of these alarms with the operators at the
Monitoring Centre .
7. MaIntenanCe
There is no requirement for any onsite maintenance
on the IRIS-4 2 Series .
If engineers want to carry out a maintenance inspec-
tion, please perform the following:
• Confirm the status of the IRIS-4 2 Series unit.
• Clear any faults on the dialler.
• Reflash IRIS-4 2 Series software to latest version.
• Test the configured communication paths
(Ethernet and/or 2/3/4G) .
• Perform full test of alarms from the alarm panel
and confirm acknowledgement of these by the
operators at the Monitoring Centre .
The IRIS-4 2 Series dialler will give a visual indication
of the current system status via the 'SYS LED' . If
this is yellow constant light the current setup of the
dialler is reporting OK, yellow flashing light means
the dialler is reporting some trouble events .
SYS LED:
Yellow Constant = OK
Yellow Flashing = Dialler is reporting
some trouble events
11