Data-Linc Group LCM100 Kullanıcı Kılavuzu - Sayfa 6

Modem Data-Linc Group LCM100 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Data-Linc Group LCM100 10 sayfaları. Line carrier modem

DATA-LINC
LCM100 Technical Specifications
Power requirements
Data Rate
Data Formats
Operation
Receive Sensitivity
Transmit Level
Interface
Mating Connectors
FSK Carrier
Indicators
Environment
Dimensions
Technical Support
Data-Linc Group maintains a fully trained staff of service personnel who are capable of providing
complete product assistance. They can provide you with technical, application and
troubleshooting, spare parts and warranty assistance. Our technical staff are based in Redmond,
Washington USA and may be reached at 425.882.2206 or email [email protected]
Product Warranty
Data-Linc Group warrants equipment of its own manufacture to be free from defects in material
and workmanship for one year from date of shipment to original user. Data-Linc Group will
replace or repair, at our option, any part found to be defective. Buyer must return any part
claimed defective to Data-Linc Group, transportation prepaid.
Return Material Authorization
If a part needs to be sent to the factory for repair, contact Data-Linc Group's corporate office and
request a Return Material Authorization (RMA) number. The RMA number identifies the part and
the owner and must be included with the part when shipped to the factory.
Contact Information
Corporate Office
PN 161-09998-001A
GROUPp
120 volts at +/- 10%, 50-60 Hz, 4.5 watts. Power is on when
module(s) are connected
Up to 9600 baud
Any serial asynchronous format up to 9600 baud
Full Duplex
20 millivolts
250mW into 3 ohms
EIA RS-232C Interface Standard
Female, DB-25P
Highband: Space 150 kHz, Mark, 156.5 kHz
Lowband: Space 100 kHz, Mark, 106.5 kHz
Bandwidth: 10 kHz
Power: Red LED indicates power on
Carrier Detect: Green LED indicates carrier signal is being
received over power line from other module
Operating Temperature: 32
o
Storage: -40to 185 F (-40
Humidity: Up to 90% (non-condensing)
7.25" x 4.85" x 2.55" (184mm x 123mm x 64mm)
Data-Linc Group
3535 Factoria Blvd. SE
Suite 100
Bellevue, WA 98006
Telephone: 425.882.2206
Fax: 425.867.0865
Web site: www.data-linc.com
Get other manuals https://www.bkmanuals.com
LCM100 User's Guide
o
o
o
to 158
F (0 to 70
C)
to 85 C)
5