Diagram 6
Electrical Connections
AVX230SN/AVX230WSN
AVX230PN/AVX230WPN
AVX230MPN/AVX230WMPN
230MP/300MP MODEL
EXTRACT ONLY
230/300 BASIC MODEL
EXTRACT ONLY
L
N
L
L
1
2
1
2
3
4
LIVE IN
NEUTRAL IN
NUMBER
TERMINALS
1
2
3
4
L
N
L
L
1
2
MODELS
AVX230AN/AVX230WAN
230A/300A MODEL
EXTRACT ONLY
EXTRACT ONLY
L
N
L
L
2
1
1
2
3
4
LIVE IN
NEUTRAL IN
Diagram 7
WIRING DIAGRAM
For the 230AN/300AN model using the reversible 2 speed controller Part No.
AVACTRL2R and the variable, reversible speed controller part no. AVACTRLVRN
230AN/300AN
L
N
L
L
230A/300A
1
2
1
2
3
4
EXTRACTOR FAN
IMPORTANT
When fitting a controller
(AVACTRL2R/AVACTRLVRN) remove
bridge wire from terminal block.
L
N
L
L
N
L
REVERSIBLE
1
2
SPEED CONTROLLER
1
2
3
4
5
6
LIVE IN
NEUTRAL IN
Telephone: 01179386400 Fax: 01179386401
Victoria Road Avonmouth Bristol BS11 9DB
077185
AVX230SN/AVX230WSN
AVX230PN/AVX230WPN
AVX230MPN/AVX230WMPN
230MP/300MP MODEL
INPUT ONLY
230/300 BASIC MODEL
INPUT ONLY
L
N
L
L
1
2
1
2
3
4
LIVE IN
NEUTRAL IN
TYPICAL INTERNAL
WIRING LAYOUT
POWER
SUPPLY
MODELS
AVX230AN/AVX230WAN
INPUT ONLY
230A/300A MODEL
INPUT ONLY
L
N
L
L
2
1
1
2
3
4
LIVE IN
NEUTRAL IN
Installation Instruction for
WARNING.
All window fan models are to be installed using a flexible supply cord and are supplied with a
supply cord with an internal cord anchorage.
All wall fan models are for fixed wiring only, a flexible cord must not be used.
THROUGH A WINDOW (ALL MODELS DIAGRAMS 3/4).
1. Cut a hole in the glass to suit fan. This is best cut by a qualified glazier, alternatively,
measure your window and get a new piece of glass with a pre-cut from your glass
merchant and replace.
Hole Size Ø
230mm 260 Ø
300mm 320 Ø
Caution – do not over tighten these screws as it is possible that you might crack
the glass, replace the external grille.
3. Electrical: All wiring must comply with current IEE Regulations. If in
any doubt call a qualified electrician.
NOTE: All flaps should open and close together. If they do not, remove the second
flap and remove and replace until it locates properly.
Connect the cable from the fan to a double pole fused spur having a contact
separation of at least 3mm in all poles, must be used and fitted with a 3 amp fuse,
and should be sited outside any room containing a shower or fixed bath. The fan
should not be accessible to a person using either the shower or the bath.
THROUGH WALL FIXING (ALL MODELS DIAGRAMS 1,2&5)
4. Cut a hole through the wall to suit fan and duct then fit the aluminium flexible duct
through the wall (wall fixing kit supplied separately - AVA295/230mm - AVA302/300mm)
making sure that there is a slight tilt to the outside in case any water gets in through the
external grille so it will not run into the room. Make good around the duct. If rigid duct
is used to install the fan it must be a minimum of 290mm long, if flexible duct is used
to install the fan it must be a minimum of 500mm (19 1/2 ") from the fan to the outlet
grille
0908
the AVX 230/300 Range
2. Remove external grille by gently levering the top out with a
small screwdriver and remove the four pozidrive screws and
separate the two halves.
Hold the fan in position over the hole on the inside of the
window and then refit the four pozidrive screws from the
Outside.(Diagrams 1/2)