Elsema iS260 Kullanıcı Kılavuzu - Sayfa 9
Kapı Açıcı Elsema iS260 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Elsema iS260 11 sayfaları. Swing gate opener
1.3 TECHNICAL FEATURES:
Motor Voltage
Gear Type
Nominal Thrust
Stroke Length (CD)
Power Supply
Nominal Input Current
Maximum Operating Current
Maximum Gate Weight
Maximum Gate Length
Duty Cycle
Operating Temperature
Dimension
B Dimension:
1.4 MAINTENANCE
Maintenance should be performed at least every six months. If it is used in high traffic area, a
more regular maintenance should be performed.
Disconnect the power supply
Clean and lubricate the screws, the pins and the hinge with grease.
(1)
Check the fastening points are properly tightened.
(2)
Check and make sure that the wire connections are in good condition.
(3)
Connect the power supply
(1)
Check the power adjustments.
(2)
Check the function of the manual release
(3)
Check the photocells or other safety device.
:
:
:
iS260/iS260D SWING GATE OPENER MANUAL
24Volts DC motor
Worm gear
2000N
400mm
240 Volts AC
2 Amps
4.2 Amps for maximum 10 sec
200 kg per leaf
2.5 metres
20%
-20°c ~ +50°c
819mm x 197mm x 100mm
7