Top Panel
V2、V4:6SN7
1.
A1、A2、A3、A4:KT88/EL34
2.
Turn the Tube SEL. to position KT88 on the
rear panel, if you are going to use KT88 Tube.
Turn the Tube SEL. to position EL34 on the
rear panel, if you are going to use EL34 tube.
V1、V3:6SL7
3.
Bias Adjustment (A1、A2、A3、A4)
4.
Used to adjust bias of corresponding power
tube(A1、A2、A3、A4)
Bias Meter
5.
Used to monitor the working current of the
power tube.
◆ Be careful of the high temperature of the tubes during operation.
◆ Please replace the power tubes after switch off in 20 minutes, and follow the suggetion to unplug the
inset the tubes.
◆ Power tubes must be matched for well function.
◆ Forbidden to make the pointer of the bias meter out of the A zone when adjusting the power tube.
◆ Make sure the supply voltage is 230V before bias adjustment.
◆ Even under normal working state, the point of the bias meter could move for the voltage fluctuation.
9
1
2
3
4 5
Bias adjustment for the power tube:
Turn the Bias Selector Switch to its opposite direction
without releasing it, adjust the corresponding Bias
Adjustment Swith with flat screwdriver, and inspect the
Bias Meter on the top panel to make sure the pointer
keeps in the certer. Bias adjustment for A1.A2,A3 and A4
are the same.After all have been djusted, do it one more
time to make sure all the bias level of A1,A2,A3 and A4
are the same.
Sample of bias adjustment for power tube A1:
1. Turn the Bias Selector Switch A1 to its opposite
direction without releasing it.
2. Adjust the corresponding Bias Adjustment Switch A1
with flat screwdriver until the pointer of the bias meter
keeps in the center. The same for A2, A3 and A4.
NOTE
Diagram 4
Bias meter when not working
A
Diagram 5
Bias meter during working
Note: When working normally,
the pointer should stay within
the A zone, still , it would move
for the voltage fluctuation.