Dust Free 04401MV Kurulum ve Kullanım Kılavuzu - Sayfa 7
Hava Temizleyici Dust Free 04401MV için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. Dust Free 04401MV 8 sayfaları. Ultraviolet light systems
BIO-FIGHTER
®
NOMAD, NOMAD 2 INSTALLATION & OPERATION MANUAL
TROUBLESHOOTING
Maintenance and troubleshooting should be
performed by a qualified technician.
Device fails to operate.
1. Check that device is connected to proper
power.
2. Check that fuse is in good working order.
Replace with fuse if necessary.
3. Check that ballast is receiving correct
power. Replace ballast if necessary.
4. Check continuity of lamp filaments.
(Replace lamp if necessary.)
5. Check that wires are properly connected to
lamp and ballast.
6. Check that lamp is properly connected to
lamp receptacle.
FUSE REPLACEMENT
1. Disconnect power.
2. Unscrew the knob marked "Fuse" and
remove fuse.
3. Install new fuse and screw knob back in
place. Only use a 250V/3 amp fuse.
4. Reconnect power.
WARNING
Burn Hazard.
During replacement, allow lamps to cool 10 minutes
before removing them. Personal injury may result.
WARNING
Mercury Hazard. Do Not Break.
Each UV-C lamp contains a small amount of Mercury.
May cause redness or irritation. Use proper disposal
techniques in case of breakage.
LAMP REPLACEMENT(Annually)
The lamp should be replaced annually even if
it appears to be operating normally. UV-C
energy production diminishes over time.
1. Obtain the correct replacement lamp for
your model.
2. Disconnect power to the equipment. Allow
lamp to cool 10 minutes before touching.
3. Remove old lamp and install new lamp.
See page 5.
4. Reconnect power. For Nomad 2 make sure
power switch is in the "ON" position.
5. Use viewport to verify operation.
LAMP DISPOSAL
Dispose of your spent UV-C lamps at your
local recycling center. You may also send your
spent lamps in the same container you
received your replacement lamps to:
Dust Free® Lamp Reclamation
1112 Industrial Drive
Royse City, TX 75189
PROPER CLEAN-UP TECHNIQUE IN CASE OF
LAMP BREAKAGE
Wear protective gloves, eyewear and mask.
●
Sweep the broken glass and debris into a plastic
●
bag, seal the bag, and dispose of properly.
Contact your local waste management office for
proper disposal.
Do not use a vacuum cleaner. Do not
●
incinerate.
Replacement Parts
UV-C Lamp - 9"
UV-C Lamp - 16"
Ballast - Nomad - 9"/16", Nomad II - 9"
Ballast - Nomad II - 16"
Remote Safety Interlock
Fuseholder
Fuse
Lighted On/Off Switch Nomad II 120V/230V
For information on the dealer in your area call: 1-972-635-9565.
Visit us at http://www.dustfree.com
7
Part No.
06035
06036
06149
06167
06150
212225-00
750-0108-001
750-0026-002