Luminescence sensor
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED
The yellow LED ON indicates that the N.O. (normally open) output status
is closed.
READY/ERROR LED (bicolour)
When the bicoloured LED is continuously green, the sensor is operating
in a normal condition and it is ready to function correctly (stability
condition).
The red and green blinking of the LED indicates a wrong sensor setting.
Please refer to the "SETTING" paragraph to get the correct setting
procedure.
SET PUSHBUTTON
A long pressure on the pushbutton activates the self-setting procedure.
INSTALLATION
S5N-PA...U: The sensor can be fixed by means of the M18x1 threaded
body through a 18 mm hole, using the specific washer and the
enclosed 24 mm nuts (maximum torque of tightening 1.5 Nm).
Alternatively, the sensor can be mounted through the two housing's holes
using two screws (M3x22 or longer) and nuts.
Amongst the various possible solutions, we suggest to choose the
combination that offers the best visibility of the signalling LEDs and the
easiest access to the SET pushbutton.
22 mm nuts, h=8 mm, (2 Nm maximum tightening torque) are available to
guarantee an improved torque.
S5N-MA...U: The sensor can be fixed by means of the M18x1 threaded
body through a 18 mm hole, using the specific washer and the two
CH.24 nuts enclosed (22 Nm maximum tightening torque).
For both plastic version and metallic version are available various
orientable fixing brackets to ease the sensor positioning (please refer to
the accessories listed in the general catalogue).
10...15°
The operating distance is measured
from the front surface of the sensor
lens.
To detect luminescent marks on
reflective
surfaces,
position the
sensor axis at 10°...15° respect to
the orthogonal line of the surface to
detect.
The connections are compliant to the EN 60947-5-2 standard.
BROWN
1
+
WHITE
2
4
BLACK
BLUE
3
S5N-PA VERSIONS
S50-PA VERSIONS
81.5
2
1.5
3.5
4
4
25
43
2.5
SET PUSHBUTTON
N°.2 Ø3.8
OUTPUT LED
34
15
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating mode:
Data retention:
Operating temperature:
Storage temperature:
Insulating strength:
Insulating resistance:
Operating distance (typical
values):
Minimum spot dimension:
Emission type:
Ambient light rejection:
Vibrations:
Shock resistance:
10...15°
Housing material:
Lens material:
Mechanical protection:
Connections:
→
Weight:
AtEx 2014/34/EU
CONNECTIONS
M12 CONNECTOR
10 ... 30 Vdc
N.C. OUTPUT
N.C. OUTPUT
(WHITE)
0 V
N.O. OUTPUT
(BLUE)
0 V
DIMENSIONS
S50-MA VERSIONS
14.5
67
S5N-MA VERSIONS
4
4
CABLE VERSION
10
43
10
2.5
READY/ERROR LED
READY/ERROR LED
OUTPUT LED
49
mm
TECHNICAL DATA
S5N-PA PLASTIC VERSIONS
10 ... 30 Vdc (limit values)
2 Vpp max.
25 mA max.
N.O. and N.C.; PNP or NPN (short-circuit protection)
100 mA max.
2 V max.
500 s
1 kHz
OUT PUT LED (YELLOW) / READY/ERROR LED (GREEN/RED)
SET pushbutton
LIGHT mode on N.O. output / DARK mode on N.C. output
non volatile EEPROM memory
-10 ... 55 °C
-20 ... 70 °C
500 Vac 1 min., between electronics and housing
>20 M 500 Vdc, between electronics and housing
8...20mm range, maximum signal at 10 mm
3 mm
LED UV (370 nm)
according to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
PBT
PMMA
IP67 Metal versions type 1 enclosure
2 m cable 4 mm / M12 - 4 pole connector
75 g. max. cable vers.
25 g. max. connector vers.
II 3D EX tc IIIC IP67 T 85°C
The supplied sensor is set at the maximum sensitivity, allowing
the detection of the minimum luminescence intensity. No other
setting procedure is necessary, unless luminescent objects placed
on luminescence backgrounds have to be detected.
EASY TOUCH
+
10 ... 30 Vdc
The sensor uses the patent-covered EASY TOUCH technology that
2
1
allows a rapid and safe self-setting of the product.
(BROWN)
Two different setting possibilities are available:
3
4
-
- EASY TOUCH
N.O. OUTPUT
(BLACK)
setting.
- FINE DETECTION; to be used only in particularly critical conditions,
this setting procedure is used only when the EASY TOUCH is not
sufficient.
Setting of S5N-PA/MA...U
To achieve a correct sensor functioning, the luminescence mark or
object to be detected has to be placed at the right reading distance.
- EASY TOUCH
14.5
The EASY TOUCH technology allows the functioning in the LIGHT
mode (mark presents a higher luminescence respect to the
background).
The mark to detect has to be placed correctly at the right reading
distance within the sensor spot.
Press the SET pushbutton until the READY/ERROR LED turns OFF.
Release the SET pushbutton and wait for the READY/ERROR LED to
CABLE VERSION
turn green.
10
10
The sensor is now ready to detect the pre-set luminescent mark or
SET PUSHBUTTON
object (output LED turns ON when the NO output is closed).
Note: The automatic EASY TOUCH setting has to be performed
without any objects inside the sensor reading range (or using a non-
luminescent object) in order to bring the sensor back to the maximum
READY/ERROR LED
READY/ERROR LED
sensitivity condition.
OUTPUT LED
OUTPUT LED
- Fine detection (DARK or LIGHT m ode)
This mode offers an improved detection precision and aIso allows the
detection of luminescent marks or objects placed on luminescent
backgrounds.
S5N-MA METALLIC VERSIONS
The operating mode is selected automatically by the sensor:
DARK operating mode (mark presents a lower luminescence respect
to the background) or LIGHT operating mode (mark presents a higher
luminescence respect to the background).
The mark to detect has to be placed correctly at the right reading
distance within the sensor spot.
Press the SET pushbutton. The READY/ERROR LED turns OFF.
Keep the SET pushbutton pressed until the READY/ERROR LED
blinks green. Place the background under the sensor spot.
Press the SET pushbutton again until the READY/ERROR LED turns
OFF. The sensor is now ready to detect, with a very high precision, the
pre-set luminescent mark (output LED turns ON, READY/ERROR
LED turns green).
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.
Nickel plated brass
© 2007 - 2020 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Without
110 g. max. cable vers.
limiting the rights under copyright, no part of this documentation may be reproduced, stored in
or introduced into a retrieval system, or transmitted in any form or by any means, or for any
60 g. max. connector vers.
purpose, without the express written permission of Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many
countries, including the U.S.A. and the E.U. All other trademarks and brands are property of
their respective owners. Datalogic reserves the right to make modifications and improvements
without prior notification.
SETTING
; a long pressure of the SET pushbutton allows self-
(standard detection in the LIGHT m ode)
For information about the disposal of Waste Electrical and Electronic
Equipment (WEEE), please refer to the website at www.datalogic.com.
821006252 Rev.C