Datamax H-Class Manuel - Sayfa 8

Barkod okuyucu Datamax H-Class için çevrimiçi göz atın veya pdf Manuel indirin. Datamax H-Class 8 sayfaları. Cutter option
Ayrıca Datamax H-Class için: Hızlı Başlangıç Kılavuzu (12 sayfalar), Manuel (14 sayfalar), Manuel (10 sayfalar), Manuel (12 sayfalar)

Datamax H-Class Manuel
This is the optimum
power level and tag
position that was
established and set
in the printer during
the RFID Calibration
process.
Step 4: RFID Programming Modes
The printer features two different operational modes for tag programming:
Direct Mode allows user (Host) control of RFID reading and writing, where each tag is individually
processed with status and data responses.
Label Formatting Mode uses the printer configuration to process all RFID read, write, and
exceptions as determined by a label format, and supports automatic increment and decrement
commands for numeric, alphanumeric, or hexadecimal.
Note: (1) Both programming modes will auto-position to the RFID tag location.
(2) Reference the Class Series 2 Programmer's Manual for detailed programming information.
RFID TAG REPORT
WED 09:52AM 12 APR2006
POWER LEVEL
0dB
RFID POSITION
1.41in.
OUTCOME
POSITION
1.10in.
RW
1.14in.
1.18in.
RW
RW
1.22in.
RW
1.26in.
RW
1.30in.
1.33in.
RW
RW
1.37in.
RW
1.41in.
RW
1.45in.
1.49in.
RW
1.53in.
RW
RW
1.57in.
RW
1.61in.
RW
1.65in.
1.69in.
RW
RW
1.73in.
1.77in.
R
1.81in.
1.85in.
These are tested tag
positions and outcomes,
where:
RW = Read/Write;
R = Read; and
blank = unreadable.
6
OUTCOME
POWER
RW
-4dB
-3dB
RW
RW
-2dB
RW
-1dB
RW
0dB
1dB
RW
RW
2dB
RW
3dB
RW
4dB
After establishing the
tag position, these are
the tested power levels
and outcomes, where:
RW = Read/Write;
R = Read; and
blank = unreadable.