Step 14: Power up and calibration
Make sure to plug the power cable into the 2x5 header, NOT the 2x8 EXPANDER header. If you connect
the EXPANDER header to power, it will DAMAGE THE MODULE.
Use the supplied 10-to-16pin power cable to attach the 2x5 "POWER" header to a standard Eurorack
power supply. The red stripe on the cable should be down, matching the white stripe on the PCB.
Before turning on the power supply, use the 16-to-16pin cable to attach the EXPANDER header on the
QCD Expander to the EXPANDER header on a QCD module. The red stripe should be orientated down
on both the expander and the main module.
Power up, and tap the QCD's button to set a tempo. The lights on the QCD Expander should flash. If not,
unplug immediately and check around for errors. Make sure both cables aren't backwards. Feel all the
ICs and the 7805 to see if anything got hot. If there's a problem, skip to the Troubleshooting section.