Aussie Vantage 2200 Montaj ve Kullanım Kılavuzu - Sayfa 14
ızgara Aussie Vantage 2200 için çevrimiçi göz atın veya pdf Montaj ve Kullanım Kılavuzu indirin. Aussie Vantage 2200 16 sayfaları. Portable lp gas grill
Ayrıca Aussie Vantage 2200 için: Montaj ve Kullanım Kılavuzu (16 sayfalar)
Problem
Burner will not light
using a match
Flames blow out
Flare up
Persistent grease fire
Humming or whistling
from the regulator
Low flame or low heat
If your problem is not resolved from the information provided above, please call Customer Service at
TROUBLESHOOTING (cont'd)
Possible Cause
Excess flow valve tripped in
Regulator
Obstructions in burner
Electrode and burner are wet
Wire is loose or disconnect-
Wire is shorting (sparking
between ignitor wire and
electrode
Burner not assembled
correctly
LP gas cylinder is empty
Excess flow valve tripped in
Regulator
Obstructions in burner
High or gusting winds
Gas in LP cylinder is low
Grease build up
Excessive fat in meat
Grease trapped in Bowl and
around burner system
Outside temperature, humidi-
ty, barometric pressure, and
the gas level within the tank
may cause the rubber
diaphragm inside the regula-
tor to vibrate, making a hum-
ming or whistling sound.
Gas in LP cylinder is low
Solution
Turn Control Knob to "OFF" position. Wait five minutes. Relight
LP gas grill. If flame remains to be low, turn off gas.
Disconnect the Lp gas cylinder from the Regulator. Reconnect
the LP gas cylinder to the Regulator. Perform a leak test.
Relight grill. This will reset the excess flow valve.
Clean burner (See How to Clean the Burners in Care and
Maintenance section of this manual).
Dry electrode with clean cloth
Reconnect the wire
Replace ignitor wire/electrode assembly (Call the Customer
Service Department @ 1-800-251-7558)
See burner re-assembly in How to Clean the Burners.
Dispose of empty cylinder and replace with a full one.
Turn Control Knob to "OFF" position. Wait five minutes. Relight
LP gas grill. If flame remains to be low, turn off gas. Disconnect
the Lp gas cylinder from the Regulator. Reconnect the LP gas
cylinder to the Regulator. Perform a leak test. Relight grill. This
will reset the excess flow valve.
Clean burner (See How to Clean the Burners in Care and
Maintenance section of this manual).
Turn front of grill away from wind or increase flame height.
Check LP gas cylinder. Replace if necessary.
Clean grill
Trim fat from meat before grilling
Turn Control Knobs "OFF". Let fire burn out and remove Cooking
Surfaces. After the grill cools, clean all parts.
Although this sound may be alarming, this is NOT dangerous as
long as it is not accompanied by the smell of gas. Simply adjust
the burner settings and usually the sound will subside. If the
humming sound persists, a change in atmospheric conditions will
eventually stop the vibration. Should you smell gas, do not use
the grill and call Customer Service at 1-800-251-7558
Check LP gas cylinder. Replace if necessary.
1-800-251-7558.
14