DETERGENT APPLICATOR (CLEANING AGENTS)
Step 1: -
Fill detergent tank with detergent:
The Concept F140 detergent tank is incorporated into the
chassis of the machine.
never pour detergent into the tank unless it has been diluted
down. If the detergent is too thick, this will cause blockage
through the detergent injector (Fig. 7).
Step 2: - The vario nozzle on the Concept F140 has a separate
extreme low pressure function which creates a venturi
(suction feed) to allow the detergent to self feed through the
detergent injector. To perform this operation, the vario
nozzle on the machines listed above can be clicked forward,
creating the venturi. The nozzle should click forward approximately 2cm. The
detergent will only operate when the unit is on its extreme low pressure function.
Step 3. - Once operator has finished with the detergent, then warm water should be filled
into the detergent tank and Step 2 should be repeated to avoid the detergent
sticking inside the detergent injector of the machine.
Never let detergent dry on objects.
Never use caustic or acidic materials through detergent function facility.
TOTAL STOP ADJUSTMENT
Total Stop is a unique device that automatically turns the machine off when the operator
releases the trigger. Total Stop can move out of adjustment through wear or being knocked or
jarred.
IMPORTANT: Aussie Eco-Clean recommend o-rings must be replaced when carrying out any
maintenance and repair work. All moving parts, screws and sealing rings must be coated in
marine grease prior to use.
accessories can cause the Total Stop function not to work (this will cause the machine to
pulsate).
NOTE: The machine's permissible working pressure has been set on
the safety unloader by the manufacturer and MUST NOT BE
CHANGED. The unloader is sealed for this reason. The permissible
working pressure must be re-set after all repairs and the unloader re-
sealed with paint on unloader lead.
REMOVAL AND INSTALLATION
-
Remove motor and pump group from chassis and covers.
-
Unscrew hex bolts (Fig. 8).
-
Take note of adjusting screw for micro switch, the o-rings and
the delivery valves.
-
To replace unloader remove bypass valve.
-
Insert adjusting screw (Fig. 9) in the opening of the micro
switch (Total Stop).
-
Fix fastening screws and torque to 7NM, working crosswise.
-
Set working pressure when machine cuts off when the trigger
is released.
-
Repaint unloader seal.
If you do not feel confident to carry out this adjustment, take your machine
to your local authorised Aussie Pumps Service Agent.
When filling the detergent tank
Water leaks internally in the pump or on the high pressure
Concept F140 Cold Water Pressure Cleaners – March 09
Fig. 7
Fig. 8
Fig. 9
Page 9 of 12