WARNINGS

OVERSPEEDING
Do not operate machine at over 2400 rpm (engine
speed).
Over speeding can cause serious pump damage.
EXCESSIVE BYPASS
Do not run on excessive by-pass.
Switch machine off within five minutes of ceasing
operation as excessive by-pass can cause heat build
up in pump and subsequent damage.
Excessive bypass running voids warranty.
PRESSURE CLEANER DAILY CHECKLIST
1. Check pump & gearbox oil level
2. Check engine oil level
3. Check nozzle for wear
4. Check all high pressure components for leaks,
damage, wear or corrosion.
a. gun/lance
b. High pressure hose
c. all fittings
5. Check water filter and clean regularly
6. Check unloader, safety valve and thermal dump for
leaks
BEWARE
of abrasions on hose and replace if damaged
...
STAY SAFE
SERVICE ADJUSTMENTS
Note only qualified approved technicians should
carry out adjustments or major service work on
these pumps.
HIGH PRESSURE SETTING
The high pressure pump is factory set to operate at
its rated pressure.
DO NOT ADJUST.
regulator will void warranty and can be DANGEROUS.
CHECK NOZZLE MONTHLY
If pressure drops off check nozzle for wear.
Nozzles should be replaced on a regular basis (every
month for machines in regular use, every three
months for machines used intermittently).
Using the machine with the incorrect nozzle size or
worn nozzle will void warranty and can be
DANGEROUS to the operator.

THREE MONTHLY REGULAR SERVICE

All professional machines need to be thoroughly
serviced every three months. Use an approved and
qualified Aussie service agent. The service should
include the engine manufacturer's recommendations
(see separate Engine Manual) and the following:
1. Change pump & gearbox oil
2. Check filter for foreign debris
3. Check unloader, safety valve and thermal dump for
leaks
4. Check all HP components for leaks: Gun/lance, HP
hose and all fittings
5. Replace nozzles
6. Check gearbox to engine key for wear, and replace
as required. NB Damage generated by worn keys is
not covered by warranty.
Australian Pump Industries Pty Ltd
7 Gladstone Road, Castle Hill NSW 2154
Ph: (02) 8865 3500 Fax: (02) 9894 4240
www.aussiepumps.com.au [email protected]
Tampering with the pressure