DVS D103/V2/AUTO Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 7
Kontrol Ünitesi DVS D103/V2/AUTO için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. DVS D103/V2/AUTO 8 sayfaları. Flushvalve wc flushing system with the fully automatic sensor
A WaveOn sensor can be connected to the
10
control box to enable the user to manually
flush the system.
Care must be taken when positioning the
sensor to ensure ease of use, and that general
WC cubicle occupancy cannot accidentally
trigger it.
The sensor needs to be fitted on a vertical
surface less than 2 metres away from the
control box through a 1725mm predrilled
hole, then secured with the nut, washer and
bezel provided.
Alternatively the sensor can be mounted
into the manual operating handle hole of an
exposed cistern if required. Various sensor
back plates and extensions are available from
DVS for deep wall installations.
Cable connection
Connect the sensor cable to the manual
sensor position in the control box using the
connector plug. See section 3 board layout.
Please check the cable is clean and dry
before connection onto the PCB.
IMPORTANT: Do not attempt to modify or
adjust the length of the sensor cable!
220-240V a.c
Safety
11
CAUTION! 220240V a.c.
NEVER open the cover with the supply live.
DO NOT attempt to make adjustments until the
power is isolated!
IMPORTANT: Adjustments will not be
implemented unless the supply to the control
system has been isolated.
The Green LED indicates that the system is
powered ON.
Time settings
Switch 1 = 3 second flush
Switch 2 = 2 second flush
Switch 3 = 1 second flush
Switch 4 = 0.5 second flush
Switch 5 = 0.25 second flush
The flushtime is the time set by the switches
in the on position i.e. if switch 1 and 3 are set
ON the flushtime is set to 4 seconds. This is the
default setting.
The flushtime time settings can be set from:
1 seconds to 6.75 seconds. Settings below 1
second will default to 1 second.
220-240V a.c
Flushvalve WC Flushing System Instructions Version INFL002 v2.0 180511
Key (Below):
1.
Sensor
2.
Bezel
3.
Backplate
4.
Mounting surface
5.
Washer
6.
Back nut
1
2
3
Option settings
Switch 6 = Enables the purge function. When set
to ON the system will purge if no operations have
been carried out in the last 24 hours.
Switch 7 = Enables the lock out function. When set
to ON the system will lock out if 4 operations are
carried out within 15 minutes.
Switch 8 = Set to OFF for the standard sensor.
Switch 8 = Set to ON for the Fully automatic sensor.
4
5
6
Factory settings
Page 6