4qd PRO-160-HCV Kullanım Kılavuzu - Sayfa 11

Kontrolör 4qd PRO-160-HCV için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. 4qd PRO-160-HCV 16 sayfaları.
Ayrıca 4qd PRO-160-HCV için: Kullanım Kılavuzu (16 sayfalar)

Notes:
If you are not using "Joystick" mode, you should set "Learn max reverse"
to the same value as "Learn max forward". Reverse is then selected by
the reverse switch.
Volt mode uses the "Pot learn" function for learning.

17. Power-up options

Power on with SEL pressed enters set-up mode.
Power on with DOWN pressed will start up with profile 1. This is an emergency
start option to be used should a system 'EEPROM' error occur.

18. System settings [inc reset]

18.1
About. Gives information on the model, software version, and serial number.
18.2
Factory reset. Allows the user to reset the Pro-160 to factory settings.
18.3
Firmware update. Allows new software to be installed via the uSD card reader.
Switch off the Pro-160, insert the uSD card containing the new software into the
card holder, and switch on again with SEL pressed.
Navigate through the system settings menu to "Firmware" and then follow
instructions. Remove the uSD card when finished.

19. Mounting

The Pro-160 has 4 M5 threaded mounting holes in the baseplate, shown in green
in the diagram below.
PRO-160 V2.3/2 04/20
Page 11
www.4qd.co.uk