Frontpanel description
The Dymand has two identical channels, channel 1 and 2. These channels have identical controls
(except for 'stereo-link'), therefore only one channel will be considered.
'ON'-Switch
Expander on
Expander threshold
Threshold
Ratio
10dB
Attack
Release
Meter IN/OUT
Key
Out
Chain
Locut
Monitor
Output
Stereo Link
This switch switches between 'bypass' and 'on'. When it illuminates
green it indicates the device is on. When it illuminates red it
indicates 'detection monitor' operation.
Switches the downward-expander proces on. When the proces is on
a green led illuminates.
Adjustment of the expander threshold level. This threshold is relative
to the compressor threshold (-40dB to 0dB). The expander has a
fixed ratio of 1:1.25.
Adjustment of the compressor threshold level (-20dB to +20dB)
Adjustment of the compressor ratio (1:1.5 to 1:20), 1:10 means
above threshold level at the input is 1dB at the output.
Adjustment of the process attacktime. The attacktime is the time the
compressor needs to follow the audiosignal that exceeds the
threshold level.
Adjustment of the process releasetime. The releasetime is the time
the compressor needs to recover from gainreduction after the
audiosignal has sunk below the thresholdlevel.
Switches the level-meter between input and output signal. When the
led illuminates red it indicates the meter is connected to the
outputsignal.
Switches the key-input to the detectioncircuit. This function could be
used for ducking.
Switches the outputsignal to the detectioncircuit. This function
creates another kind of compression; the (compressed) outputsignal
is used for detection.
Switches the sidechain-in signal to the detectioncircuit. The
sidechain function could be used for de-essing etc. Use the
sidechain input and output to connect, for example, an equaliser.
Switches a 80 Hz highpass-filter before the detectioncircuit. This
can be used to prevent pumping or breathing effects, or to create a
low-boost in voice-overs.
Switches the signal at the input of the detectioncircuit to the output.
This can be used to monitor the key-input or the sidechain-input.
When this function is activated the red led below the switch
illuminates, and the on switch illuminates red to indicate that
something other than the normal outputsignal is being heard.
Level adjustment for the outputsignal (-20dB to +20dB). This is used
to correct the output signal.
This switch activates the stereolink operation. When this function is
activated both the compression and the expansion process of both
channels are linked. All controls (output optional) are also linked.
Channel 1 will be the control-master. This feature saves adjustment
time when processing stereo-audio.
Operation