Austria Email VT-S 800-FRM Kullanım ve Montaj Talimatları Kılavuzu - Sayfa 7

Kazan Austria Email VT-S 800-FRM için çevrimiçi göz atın veya pdf Kullanım ve Montaj Talimatları Kılavuzu indirin. Austria Email VT-S 800-FRM 16 sayfaları. Pressure-proof large storage tank

Austria Email VT-S 800-FRM Kullanım ve Montaj Talimatları Kılavuzu
In the event of any damage, the non-observation of this regulation shall represent an improper
use and thus an exclusion of the terms and conditions of warranty.
Accessory parts by AUSTRIA EMAIL AG for these multi-purpose free-standing tanks, such as
built-in electric heaters series R and series P
screw-mounted electric heaters series SH
built-in finned tube heat exchangers series RWT
are constructed in accordance with the aforementioned requirements and may be installed –
under observation of the relevant mounting instructions – without any additional measures.

8. Corrosion Protection

8.1 Series VT-N FFM

The enamelled boiler of the series VT-N FFM is protected by a standard magnesium bar anode
(maintenance see paragraph 14).
A maintenance-free external current anode (accessory) may be installed as follows using a
reduction union piece (accessory).
Replacement of magnesium anode with 5/4" union piece against external current anode
1 Electronic pulse generator
2 Mains cable
3 Anode connecting cable
4 Anode carrier plug
5 Attachment for spanner
6 Cable connector for ground circuit
Remove magnesium anode (12). Clean thread; screw in transition piece (13) with O ring (no hemp).
Apply sealing paste to the thread of the external current anode (4) before screwing in. Screw external
current anode (8) into the transition piece (13). Connect connecting cable (3) from casing (1) to the
external current anode (7) using plug.
Caution: Connect ground cable (6) to transition piece using screw M6 (14).
8.2 Series VT-N FRM and FRMR
The enamelled boiler of the series VT-N FRM & FRMR is protected by a standard magnesium bar
anode (maintenance see paragraph 14), which is screwed into a 5/4" coupling sleeve at the front of
the boiler.
7 Cable connector for anode circuit
8 Anode
9 Operating display – LED
10 Assembly loops
11 Ring for ground circuit
7