Bender B94053005 Hızlı Başlangıç Kılavuzu - Sayfa 2

Monitör Bender B94053005 için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Bender B94053005 8 sayfaları. Multi-channel residual current monitors for earthed ac, dc and ac/dc systems (tn and tt) ac, pulsed dc and ac/dc sensitive

Bender B94053005 Hızlı Başlangıç Kılavuzu
Diese Kurzanleitung ersetzt nicht das Handbuch!
Stellen Sie sicher, dass das Personal das Handbuch
und die Sicherheitshinweise gelesen und verstanden
hat.
i
Lesen Sie ergänzend zu dieser Kurzanleitung
das Handbuch D00067
Herunterladbar auf: www.bender.de/service-
support/downloadbereich
Typ /Type
Art.-Nr./Art.-No.
RCMS460-D-1
B 94053001
RCMS460-D4-1
B94053009
RCMS460-D-2
B94053002
RCMS460-D4-2
B94053010
RCMS460-L-1
B94053003
RCMS460-L-2
B94053004
Lieferumfang
...
1 RCMS4
, Bender-Sicherheitshinweise, diese
Kurzanleitung
Bestimmungsgemäße Verwendung
Die Differenzstrom-Überwachungsgeräte RCMS4...
lokalisieren Differenz- und Betriebsströme in TT- und
TN-S-Systemen. Wahlweise können auch Digital-
eingänge abgefragt und ausgewertet werden.
Für eine allstromsensitive Messwerterfassung (Typ B)
sind die geschlossenen Mess stromwandler der Serien
CTUB100 und CTBS25 erforderlich. Für diese Mess-
strom wandler wird ein 24 V DC-Netzgerät (z. B. der
Serie STEP-PS) benötigt.
Für Wechsel- und Pulsströme (Typ A) werden die
Messstromwandler der Serien CTAC... (geschlossen),
WR... (rechteckig), WS... (teilbar) und WF... (flexibel)
eingesetzt.
Die verschiedenen Messstromwandler können in be-
liebiger Kombination an die Messkanäle der Aus-
werte geräte angeschlossen werden. Beachten Sie
die im Handbuch angegebenen Grenzen des
Einsatzbereichs. Eine andere oder darüber hinausge-
hende Benutzung gilt als nicht bestimmungsgemäß.
I
eines elektrischen Schlages!
G
efahr
Stellen Sie vor Einbau des Gerätes und vor
Arbeiten an den Anschlüssen des Gerätes
sicher, dass die Anlage spannungsfrei ist.
Außerdem drohen Sachschäden an der elektri-
schen Anlage und die Zerstörung des Gerätes.
2
RCMS460-490_D00067_00_Q_XXDE / 03.2021
...
AC 50/60 Hz, 24...60 V / DC 24...75 V
Display
AC 50/60 Hz, 100...240 V / DC 100...240 V
AC 50/60 Hz, 24...60 V / DC 24...75 V
7-Segment
AC 50/60 Hz, 100...240 V / DC 100...240 V
This quickstart guide does not replace the manual!
Make sure that the relevant personnel has read the
manual and understood all instructions relating to
safety.
i
In addition to this quickstart guide, read the
manual D00067
www.bender.de/service-support/downloadbe-
reich
U
S
...
1 RCMS4
, Bender safety instructions, this quick-
start guide
The residual current monitors RCMS4... locate resi-
dual and operating currents in TT and TN-S systems.
Optionally, digital inputs can also be scanned and
evaluated.
The closed measuring current transformers of the
CTUB100 and CTBS25 series are required for AC/DC
sensitive measured value acquisition (type B). A 24 V
DC power supply unit (e.g. STEP-PS series) is required
for these measuring current transformers.
For alternating and pulsing currents (type A) the
measuring current transformers of the series CTAC...
(closed), WR... (rectangular), WS... (split-core) and
WF...(flexible) are used.
The various measuring current transformers can be
connected to the measuring channels of the evalua-
tion units in any combination. Observe the limits of
the application range specified in the manual. Any
other use or use beyond this is considered improper
use.
I
of electric shock! Before fitting the de-
D
anGer
vice and prior to working on the device con-
nections, make sure that the power supply has
been disconnected and the system is dead.
The electrical installation may sustain damage
and the device be destroyed beyond repair.
...
, downloadable from:
Typ/Type
Art.-Nr./Art.-No.
RCMS490-D-1
B94053005
RCMS490-D4-1
B94053011
RCMS490-D-2
B94053006
RCMS490-D4-2
B94053012
RCMS490-L-1
B94053007
RCMS490-L-2
B94053008
Scope of delivery
Intended use