Nem Alıcı BENDIX AD-9si için çevrimiçi göz atın veya pdf Hizmet Verileri indirin. BENDIX AD-9si 16 sayfaları. Oil coalescing air dryer
Compressor
Control
Port
Turbo
Cut-Off
Valve
(Closed)
Supply
Port
Safety
Valve
Figure 5 – Bendix
AD-9si
®
TURBO CUT-OFF FEATURE
(Refer to Figures 3 & 5)
The primary function of the turbo cut-off valve is to prevent
loss of engine turbocharger air pressure through the
Bendix
AD-9si
air dryer when the dryer is in the purge
®
®
mode.
At the onset of the purge cycle, the downward travel of the
purge piston is stopped when the turbo cut-off valve (the
tapered portion of the purge piston) contacts its mating
Oil
Coalescing
Filter
Control
Line
Exhaust
Purge
Valve
Air Dryer without a Governor — Purge Cycle
®
Desiccant
Bed
Purge
Orifice
Purge Air
Extended
Purge
Port
Delivery
Check
Valve
metal seat in the purge valve housing. With the turbo
cut-off valve seated (in the closed position), air in the
compressor discharge line – as well as the AD-9si air dryer
inlet port – cannot enter the air dryer. By completing these
actions, the turbo cut-off effectively maintains turbocharger
boost pressure to the engine.
Rear
Reservoir
Front
Reservoir
Delivery
Port
7