dymax 39381 Kullanım Kılavuzu - Sayfa 10

Endüstriyel Ekipmanlar dymax 39381 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. dymax 39381 16 sayfaları. Uv light-curing conveyors – 18" and 25"

SYSTEM OPERATION
1. Turn on the main power to the conveyor (Figure 11).
2. Press "START" on the Conveyor Speed Controller (Figure 12). Set the Belt speed by pressing and holding the
up arrow or down arrow. Belt speed can be adjusted from 1 to 50 fpm.
3. Turn Power Supply's main power on. This is done by turning the red knob on the Power Supply Front Panel
(Figure 13) to the "ON" position.
Figure 11. Main Power Controls
4. Select "RUN UV" on the Touch Screen Interface (Figure 14).
5. Turn on the control power to the UV by pushing the green "ON" Button located on the Power Supply Front
Panel (Figure 13).
6. Select "LAMP ON 400W" on the Touch Screen Interface to start the UV Lamp (Figure 15). "LAMP
WARMING" will appear at the bottom of the Touch Screen. Once the UV Lamp is ready, "LAMP ON 400W"
will be displayed.
NOTE:
The UV Lamp must always be started at 400 W. After the UV Lamp has warmed up, a lower power
may be selected if desired.
7. Adjust the height of the UV Lamp as desired by turning the UV Irradiator's Hand Crank (Figure 16). The
height of the UV Lamp above the Belt is shown by a Scale mounted on the top of the conveyor so that
adjustments may be performed without the operator looking into the Curing Chamber.
Figure 14. Select "RUN UV" on
the Touch Screen Interface.
8. After the Power Supply is shut off there is a delay before the UV Blower shuts off. Do not shut off the power
to the main machine before the UV Blower shuts off.
Dymax WIDECURE UV Conveyor
Figure 12. Conveyor Speed
Controller
Figure 15. Select "LAMP ON 400W"
on the Touch Screen Interface.
Figure 13. Power Supply Front Panel.
Figure 16. UV Lamp's Hand Crank & Scale
10