Tridak® Model 1001 Syringe Filling System User Guide
Loading the System
Filling Material Reservoir
1. Remove the Reservoir Retainer Cover by removing the Star Nuts and Cover. Ensure the Retainer is
free and clear of any previously placed cartridges or packaging.
2. Insert the Cartridge/Fluid Path Assembly into the Reservoir Retainer.
3. Guide the Fluid Path downward, passing through the bottom of the Reservoir.
4. Press the Cartridge firmly into place until seated.
5. Replace the Reservoir Retainer Cover and tighten evenly and securely with Star Nuts until the Cover
forms a solid seal around the Cartridge.
If you experience any trouble, please contact Dymax Customer Service.
Figure 7. Material Reservoir Exploded Diagram
Cover
O-Ring
Cartridge
Cartridge Retainer
Cartridge Mating Fitting
Fluid Path
Star Nut
Star Nut