dymax ECE ZIP Shutter Kullanıcı Kılavuzu - Sayfa 11

Aydınlatma Ekipmanları dymax ECE ZIP Shutter için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. dymax ECE ZIP Shutter 20 sayfaları. For use with dymax ece flood lamp systems

ECE ZIP Shutter Electrical Interconnect
Figure 14. ECE ZIP Shutter Electrical Interconnect Diagram
1. Connect Shielded Cable (4) from J2 on rear of Power Supply (2) to J3 on rear of Reflector Housing (3).
2. Connect Cable (5) from J4 on rear of Reflector (3) to 8-Pin Connector on rear of Shutter (1).
3. Connect Plug (6) into J5 on rear of Reflector (3).
NOTE: Shutter will not operate unless the Adapter Plug is installed.
4. Install Foot Pedal to 4-Pin Connector on rear of Shutter (7).
5. Connect Power Cord to J1 on rear of Power Supply (2).

Operation

1. Check that the ECE ZIP Shutter is in the closed position and load parts to be cured on the Light Shield work
surface (preferably in line with the center of the shutter).
NOTE: The ECE ZIP Shutter incorporates a safety circuit that if the Light Shield door is opened during an
exposure cycle, it will automatically close the shutter curtain and shut the lamp off.
2. Adjust the distance from the bottom plane of the ECE ZIP Shutter to the surface to be cured.
3. Close the Light Shield Door once the parts to be cured are loaded.
4. With the Light Shield Door closed, set the exposure (ECE ZIP Shutter "Open Time") by adjusting +/- the
Timer located next to the Actuate Button on the Front Panel.
5. Open the ECE ZIP Shutter using the most convenient method for you by using Actuate Button or Foot
Switch.
NOTE: The ECE ZIP Shutter will close automatically in timed mode or will stay open until you release the
Foot Switch or Actuator Button in manual mode
Dymax ECE ZIP™ Shutter User Guide
11