Unit Operation

Low Battery Indicator

4 short warning beeps sound when battery life is depleting and unable to inflate cuff for
testing. The "
" appears simultaneously for approximately 5 seconds prior to shutting
off.
Replace batteries at this time.
No memory loss will occur throughout this process.

Blood Pressure Information

Blood Pressure
Blood pressure is the force of blood pushing against the walls of arteries. It is typically
measured in millimeters of mercury (mmHg.) Systolic blood pressure is the maximum
force exerted against blood vessel walls each time the heart beats. Diastolic blood
pressure is the force exerted on blood vessels when the heart is resting between beats.
An individual's blood pressure frequently changes throughout the course of a day.
Excitement and tension can cause blood pressure to rise, while drinking alcohol and
bathing can lower blood pressure. Certain hormones like adrenaline (which your
body releases under stress) can cause blood vessels to constrict, leading to a rise in
blood pressure.
If these measuring numbers become too high, it means the heart is working harder
than it should.
200
150
100
50
6
1 2
Example: fluctuation within a day (male, 35 years old)
Upper curve : systolic blood pressure
Lower curve: diastolic blood pressure
1 8
2 4
Time of day
19
Unit Operation

Troubleshooting

Problem
Possible Cause
Cuff is too tight or not
properly positioned on
the arm
Blood pressure
results are not
within typical range
Inaccurate test results due to
body movement or monitor
movement
Cuff fails to inflate properly
Improper operation
"
"displayed
Pressurisation is over
300mmHg
21
Blood Pressure Information
WHO Blood Pressure Classification Indicator
The BP-1307 (LA137) is equipped with a classification indicator based on established
guidelines from the World Health Organisation. The chart below (colour coded on monitor
unit) indicates test results.
Mild Hypertension
:
Blood Pressure
Solution
Firmly reposition cuff
approximately
1-2cm 1/2"
(
above the elbow joint
( See Page 12)
Sit in a relaxed position with
arm placed near heart. Avoid
speaking or moving body parts
while testing. Make sure the
monitor unit is placed in a
stationary position throughout
the testing period.
( See Page 7)
Make sure hose is properly
fastened to cuff and monitor unit
Read user manual carefully and
re-test properly.
Read user manual carefully and
re-test properly.
Severe Hypertension
Moderate Hypertension
Mild Hypertension
High-n
ormal
Normal
Optimal
mmHg
/
Classification Indicator