Gacell CT-1000 Kullanıcı Kılavuzu - Sayfa 6
Akü Şarj Cihazı Gacell CT-1000 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Gacell CT-1000 9 sayfaları.
CHARGING TIME
Different battery capacity and residual voltage would affect the charging
time. Following data is only for reference (when discharge 12V lead-acid
battery to 9V, with 5A discharge current).
LED COMMUNICATION OF ABNORMAL RESULTS
No
LIGHT(S)
.
CONDITION
Solid Red
1
Warning! LED
Flashing Red
2
Warning! LED
Slow flashing
Red Warning!
3
LED
+
Battery Size/Ah
12
20
30
40
CAUSE(S)
Reverse Polarity
1) Open-circuit
2) Dirty Battery
Posts
3) Dead Battery
(voltage below 1V)
4) Output Short
Circuit
Charging in 6V
Mode(s) for 12V
battery
Approx. Time to
Charge in Hours
(12V)
8H
11H
13H
18H
Exchange the red and
black clamps or ring
terminals to the correct
battery posts
1) Connect the red and
black clamps or ring
terminals to the battery
posts
2) Clean the battery posts
3) Replace the battery
with a new one
immediately
4) Disconnect red and
black output terminals
Please do manually press
Mode button to choose
correct charge mode.
CAUTION: If you choose
5
SOLUTION(S)