Providing all maintenance conditions have been met, follow this systematic approach to diagnosis.
1. INSTALLTION TOOL STOPS AND A RED LED COMES ON.
a.) Fasteners are used beyond the specified performance capability of the tool. Wait until the LED goes out and press the
actuator assy (VP1316) briefly again. The tool then moves to its starting positions.
2.
THE INSTALLATION TOOL COMPLETES THE CYCLE THEN STOPS.
a.) The battery (VP1086) is dead. The tool is protected by a protection circuit. The LED lights up yellow. Replace the battery
with a fully charged one. The yellow LED goes out and you can continue working.
THE INSTALLATION TOOL DOESN'T WORK WITH A FULLY CHARGED BATTERY.
a.) Ensure mandrel collection bottle (VP1002) or cover cap (VP1321) is securely mounted and fully engaged in the rear of the
installation tool activating the safety switch. (See page 9).
GB128 20V BATTERY INSTALLATION TOOL

TROUBLESHOOTING

Fault Indicator (Red / Yellow LED)
Image may not reflect actual tool
#
Cover Cap (VP1321)
6/21